Technical Information
T300 Series Clothes Dryer (Condenser)
6.3 Temperature
Measurements
6.3.1
Temperature Measurements Using a Maximum Thermometer
Simple temperature measurement is possible in an unloaded machine
using a maximum thermometer as follows:
Allow the appliance to run for about 10 minutes to allow the correct air
temperature to be reached and so that the thermostat in the fan starts
operating. Place the thermometer in the fluff filter recess in the door,
fastening it with adhesive tape if necessary and allow the appliance to run
for a further 5 minutes.
Temperature Range
Normal:
90 – 100 °C
Low:
84 – 94 °C
Table 6-7:
Temperature Range
Note:
On sensor-controlled dryers even with the temperature set at “Low”, the
normal temperature is always reached at Step 1 (6 minute timed step).
57