Technical Information
4
T 980x/T 982x
3.9
F2: Open Circuit in Heater Bank NTC (2R30) ............................. 55
3.10
F3: Drying Air NTC (1R30) Short Circuit ...................................... 56
3.11
F4: Drying Air NTC (1R30) Open Circuit ..................................... 57
3.12
F50: Motor Stalls and Heater Is On for 3 Seconds ...................... 57
3.13
F55: Overriding Time Limit Exceeded ......................................... 57
3.14
F66: Air Leakage ......................................................................... 58
3.15
F98: No Gas Ignition (T 982x only) .............................................. 58
3.16
Laundry Is Overdried/F55 (Overriding Time Limit Exceeded) ..... 59
3.17
Dryer Shuts Itself Off ................................................................... 59
4
Service ..................................................................................................... 60
4.1
Programming Mode Summary ..................................................... 60
4.2
Activating/Deactivating the Demonstration Mode ........................ 62
4.3
Service Mode Summary .............................................................. 62
4.4
Removing the Fascia, Electronic and Electronic Support Panel .. 64
100
Electrical System ................................................................................... 66
1
Technical Data ......................................................................................... 67
4
Service ..................................................................................................... 67
4.1
Fuse Replacement (T 980x only) ................................................. 67
4.2
Heater Relay Removal ................................................................. 67
List of Figures
Figure D-1: T 980x Component Layout ........................................................................... 10
Figure D-2: T 982x Component Layout ........................................................................... 11
Figure 010-1: Lid Removal .............................................................................................. 13
Figure 010-2: Front Panel Removal ................................................................................ 14
Figure 010-3: Side Panel Removal ................................................................................. 15
Figure 020-1: Door Removal ........................................................................................... 18
Figure 020-2: Door Lock Removal .................................................................................. 19
Figure 030-1: Heater Bank Removal ............................................................................... 25
Figure 030-2: Bearing Housing Attachment .................................................................... 26
Figure 030-3: Rear Bearing ............................................................................................. 26
Figure 031-1: Gas Ignition Schematic ............................................................................. 30
Figure 031-2: Onset of Drying Process, Before Gas Starts to Flow ................................ 30
Figure 031-3: Drying Process, After Gas Has Started to Flow ........................................ 31
Figure 031-4: Drying Process, Flowing Gas Ignites the Flame ....................................... 31
Figure 031-5: Drying Process after Flame Has Gone Out .............................................. 32
Figure 031-6: Port for Measuring Jet Pressure ............................................................... 34
Figure 031-7: Gas Regulation Valve ............................................................................... 35
Figure 031-8: Disconnecting the Gas Regulation Valve ................................................. 36
Figure 031-9: Attaching the Gas Connecting Line to the Gas Regulation Valve ............ 36
Figure 031-10: Tightening the Gas Regulation Valve ..................................................... 37
Figure 031-11: Gas Regulation Valve ............................................................................. 37
Figure 031-12: Gas Regulation Valve ............................................................................. 38
Figure 031-13: Gas Regulation Valve ............................................................................. 39
Figure 040-1: Fan Impeller Removal ............................................................................... 42
Figure 050-1: Sealing Strip Installation ........................................................................... 45
Summary of Contents for T 980x
Page 1: ...TECHNICAL INFORMATION T 980x and T 982x Dryers US Models 2010 Miele USA ...
Page 12: ...Technical Information 12 T 980x T 982x 010 Casing Front Panel ...
Page 16: ...Technical Information 16 T 980x T 982x 020 Door Lock ...
Page 28: ...Technical Information 28 T 980x T 982x 031 Gas Heating T 982x ...
Page 40: ...Technical Information 40 T 980x T 982x 040 Motor Fan ...
Page 44: ...Technical Information 44 T 980x T 982x 050 Air Shield Front Bearing ...
Page 49: ...Technical Information 49 T 980x T 982x 090 Fascia Panel Electronic ...
Page 66: ...Technical Information 66 T 980x T 982x 100 Electrical System ...