Technical Information
22
T 980x/T 982x
Temperature Resistance
(k
Ω
)
°F °C
Heater bank NTC
(2R30)
Drying air NTC
(1R30)
212 100 6.80
1.06
230 110 5.14
0.73
248 120 3.95
0.569
266 130 3.07
0.449
284 140 2.41
0.358
302 150 1.92
0.289
320 160 1.55
N/A
338 170 1.26
N/A
356 180 1.03
N/A
374 190 0.852
N/A
392 200 0.710
N/A
Table 030-3:
Heater Bank
and Drying Air
NTC Resistance Values
2 Function
2.1 No-Load
Detection
Only in residual moisture programs.
Senses no load or very dry laundry.
Residual moisture sensor B3/1 detects the electrical resistance of the
laundry load; if this resistance is very high, it means that the laundry is dry
or that there is no load in the drum. If this is the case, then the drying
cycle will stop within 30 seconds of starting and the message
Check load
will be displayed.
2.2 Residual
Moisture
Measurement
Residual moisture is calculated based on the electrical resistance of the
damp laundry, which is measured by a sensor between a drum rib and the
drum casing.
Note:
Only one rib is used for this measurement.
The value of this electrical resistance depends on the type of laundry, the
degree of moisture, the laundry load (weight) and the drum's rotating angle
(centrifugal force, rib contact).
Summary of Contents for T 980x
Page 1: ...TECHNICAL INFORMATION T 980x and T 982x Dryers US Models 2010 Miele USA ...
Page 12: ...Technical Information 12 T 980x T 982x 010 Casing Front Panel ...
Page 16: ...Technical Information 16 T 980x T 982x 020 Door Lock ...
Page 28: ...Technical Information 28 T 980x T 982x 031 Gas Heating T 982x ...
Page 40: ...Technical Information 40 T 980x T 982x 040 Motor Fan ...
Page 44: ...Technical Information 44 T 980x T 982x 050 Air Shield Front Bearing ...
Page 49: ...Technical Information 49 T 980x T 982x 090 Fascia Panel Electronic ...
Page 66: ...Technical Information 66 T 980x T 982x 100 Electrical System ...