Technical Information
51
T 980x/T 982x
2.4.2
Normal Drying Outcome (Residual Moisture)
Drying can be set to more damp or more dry to suit the customer's preference.
2.4.3
Delicates Drying Outcome (Residual Moisture)
Drying can be set to more damp or more dry to suit the customer's preference.
More Damp
Standard
More Dry
Delicates 4% 2% 0%
Table 090-2:
Residual Moisture, Delicates
2.4.4 Memory
With the memory function activated, the extra features selected at the start of
a program are saved. When the same program is selected again, these extra
features are automatically called up.
2.4.5 Additional
Cooldown
Phase
Applies only to residual moisture programs.
An extended cooldown time reduces the temperature of the laundry at
program end. The result is that the laundry feels less damp.
The cooldown time extension has no effect on timed drying programs.
2.4.6
Prompt to Clean Air Ducts
Operators can adjust the prompt to clean air ducts to suit their needs.
For insufficient air detection, refer to Section 090-2.7.
2.4.7 Acoustical
Acknowledgment
Set the acoustical tone to sound when a button is pressed.
2.4.8 Conductivity
Setting
The conductivity of the damp laundry is evaluated and forms the basis of
residual moisture sensing.
For residual moisture sensing, refer to Section 090-2.5.
Soft water does not conduct as well as hard water. In areas where soft water
is used, the effect of soft water on residual moisture sensing can be
compensated for with this programming function.
2.4.9 Standby
With standby activated, the panel LEDs and the drum light are dimmed after
5 minutes to save energy.
2.5
Residual Moisture Sensing
The electronic detects the conductivity in microsiemens (µS) of the laundry
via residual moisture sensor B3/1. The residual moisture of the laundry is
based on this measured conductivity value.
Summary of Contents for T 980x
Page 1: ...TECHNICAL INFORMATION T 980x and T 982x Dryers US Models 2010 Miele USA ...
Page 12: ...Technical Information 12 T 980x T 982x 010 Casing Front Panel ...
Page 16: ...Technical Information 16 T 980x T 982x 020 Door Lock ...
Page 28: ...Technical Information 28 T 980x T 982x 031 Gas Heating T 982x ...
Page 40: ...Technical Information 40 T 980x T 982x 040 Motor Fan ...
Page 44: ...Technical Information 44 T 980x T 982x 050 Air Shield Front Bearing ...
Page 49: ...Technical Information 49 T 980x T 982x 090 Fascia Panel Electronic ...
Page 66: ...Technical Information 66 T 980x T 982x 100 Electrical System ...