background image

Drain pump 

Max. temperature 

203

 

°F 

95

 °C 

Drain hose (int. diameter)  

7/8

''

 

22 [DN 22] mm 

On-site hose connector for drain hose

 

(int. diameter x length) 

7/8

''

 x 1 3/16

''    

22 

x

 30 mm 

Max. transient throughput 

6.9 gal/min 

26 l/min 

Drain pump head height (from floor level) 

39 3/8” 

1000 mm 

Vented drainage required. If ventilation is insufficient, fit Miele 
kit, Mat. no. 05238090.

 

Drain manifolds serving several machines must be of suffi-
cient cross-section. 

Dump valve

 

Max. temperature 

203

 

°F 

95

 

°C 

Machine-side drain connection (ext. diameter) 

2 15/16

''

75 [DN 70] mm 

On-site drain (int. diameter) 

2 15/16

''

75 [DN 70] mm 

Max. transient throughput 

16.4 gal/min 

62 l/min 

Vented drainage required. If ventilation is insufficient, fit Miele 
kit, Mat. no. 05238090.

 

Drain manifolds serving several machines must be of suffi-
cient cross-section. 

Fittings for base 

/ floor installa-

tion  

Miele base UG/UO 6008 

4 × metal angled brackets 

 

(to secure machine to base) 
4 × screws DIN 571 (Ø × length) 

5/16

''

 x 2 9/16

''

 8 x 65 mm 

4 × rawl plugs (Ø × length) 

1/2''

 

x

  2 3/8“ 

12 x 60 mm 

Base must be bolted to the floor. Machine must be fixed to the 
base. 
Fixing materials for a floating screed floor are to be provided 
on site. 

Miele US 6008 base  

4 × metal angled brackets 

 

(to secure machine to base) 
4 × screws DIN 571 (Ø × length) 
4 × rawl plugs (Ø × length) 

1/4''

 x 2“ 6 

mm x

 50 mm

 

5/16

''

 x 1 9/16

''  

 8 

mm x

 40 mm 

Base must be bolted to the floor. Machine must be fixed to the 
base. 
Fixing materials for a floating screed floor are to be provided 
on site. 

Installation on floor or concrete base 

2 × clamps 
2 × screws DIN 571 (Ø × length) 
2 × rawl plugs (Ø × length) 

1/4''

 x 2

''              

mm x

 50 mm 

5/16

''

 x 1 9/16

''

 8 

mm x

 40 mm 

Machine must be bolted to the base or floor. Fittings are 
supplied with machine. 
Fixing materials for a floating screed floor are to be provided 
on site. 

Machine data 

Unit width 

27 9/16

''

700 mm 

28 5/8

''

727 mm 

40 3/16

''

 

1020 mm 

27 1/4

''

692 mm 

Unit

 depth 

Unit height 
Casing width 
Casing depth 

27 3/16

''

 

690 mm 

Minimum width of delivery access to installation site 

28 3/8

''

 

720 mm 
1100 mm 

Recommended rear wall gap (measured to front of machine) 43 5/16

''

 

Minimum rear wall gap (to front of machine)

 

35 7/16

''

 

Recommended rear wall gap ensures sufficient space for 
maintenance and servicing. 

900 mm 

Net weight 

309 lbs 

140 kg 

Dynamic floor load, max. 

2600 N 

2600 N 

Static floor load, max. 

1850 N 

1850 N 

Dynamic load, max. 

750 N 

750 N 

Drum frequency, max. 

22 Hz 

22 Hz 

Average heat dissipation

 

(dependent on ambient room temperature and 
program selected) 

2830 BTU/hr 

0.83 kWh 

Sound pressure (re 20 mPA),

 

workplace-related (at distance of 1 m and height of 1.6 m) 

<70 dB (A) 

<70 dB (A) 

Installation should only be carried out by authorized 

installe

rs in accordance with valid regulations! Observe installation 

instructions when installing machine! All rights reserved!  

Technical datasheet: PW 6080 LP/AV 

Date: 

2015-

Sep

-

02

Page: 1

5

 

Summary of Contents for PW 6080 EL

Page 1: ...36 15 M Nr 10 181 930 01 Installation Plan Washer extractor PW 6080 EL Electrically Heated en US ...

Page 2: ...usa com Technical Service Support Nationwide Phone 800 991 9380 Fax 800 220 1348 proservice mieleusa com 800 991 9380 609 419 4241 It is essential to read the operating and installation instructions before installing commissioning or using the machine This avoids the risk of accidents or damage All rights reserved ...

Page 3: ...1 4 UO 12 14 9 16 15 3 16 28 3 8 27 3 16 17 5 16 28 5 8 43 5 16 UG 13 1 4 52 3 16 40 3 16 UO 12 12 13 16 19 1 2 27 9 16 27 1 4 2 2 40 3 16 15 3 16 14 9 16 27 1 4 43 5 16 28 3 8 27 9 16 27 3 16 28 5 8 PW 6080 EL measurements in inches 3 ...

Page 4: ... 3 15 16 39 3 8 51 3 16 UG 13 1 4 UO 12 51 3 16 39 3 8 35 7 16 UG 13 1 4 UO 12 3 15 16 23 5 16 19 3 8 3 15 16 51 3 16 51 3 16 39 3 8 35 7 16 39 3 8 5 3 8 Version with drain pump LP PW 6080 EL measurements in inches 4 ...

Page 5: ...3 8 51 3 16 UG 13 1 4 UO 12 51 3 16 3 3 8 1 9 16 31 11 16 UG 13 1 4 UO 12 3 15 16 23 5 16 19 3 8 3 15 16 51 3 16 51 3 16 39 3 8 5 3 8 3 3 8 3 3 8 1 9 16 31 11 16 23 5 16 Version with drain valve AV PW 6080 EL measurements in inches 5 ...

Page 6: ...O 12 12 5 8 13 16 39 3 8 27 1 4 43 5 16 27 17 5 16 22 1 16 3 15 16 2 13 16 21 5 8 2 13 16 10 13 16 1 1 2 3 8 2 1 2 2 9 16 24 9 16 12 1 4 43 5 16 27 UO 26 7 8 27 1 4 UO 26 3 4 17 3 8 24 11 16 PW 6080 EL measurements in inches 6 ...

Page 7: ... 3 16 40 3 16 13 16 27 1 4 39 3 8 3 15 16 2 13 16 2 13 16 21 5 8 10 13 16 43 5 16 27 3 16 43 5 16 27 9 16 17 5 16 22 1 16 3 15 16 3 3 10 13 16 21 5 8 27 9 16 1 9 16 2 3 8 3 8 2 1 9 16 PW 6080 EL measurements in inches 7 ...

Page 8: ...PW 6080 EL measurements in millimeters 8 ...

Page 9: ... Version with drain pump LP PW 6080 EL measurements in millimeters 9 ...

Page 10: ...Version with drain valve AV PW 6080 EL measurements in millimeters 10 ...

Page 11: ...PW 6080 EL measurements in millimeters 11 ...

Page 12: ...PW 6080 EL measurements in millimeters 12 ...

Page 13: ...ured to floor Recommended height 11 13 16 300 mm Minimum height 2 3 4 70 mm Recommended width 27 9 16 700 mm Recommended depth 27 9 16 700 mm Dispensing pump External dispensing pumps 2 or 4 head pump Voltage external power supply required 120V Fusing 15A Supplied with supply cable and plug NEMA 5 15 Machine connections Electrical connection 1 Standard voltage 2 AC 220 240V 60Hz Voltage V 2 AC 220...

Page 14: ... Max pressure 145 psi 1000 kPa Max throughput 2 9 gal min 11 l min On site connection thread 3 4 garden hose thread male 3 4 garden hose thread male 61 1550 mm approx 18 5 gal hr approx 70 l hr Length of connection hose supplied 1 connection hose Hourly water demand average for 60 C program for stand ard connection with hot and cold water If hot water supply is not available connect hot water inle...

Page 15: ... 9 16 8 mm x 40 mm Base must be bolted to the floor Machine must be fixed to the base Fixing materials for a floating screed floor are to be provided on site Installation on floor or concrete base 2 clamps 2 screws DIN 571 Ø length 2 rawl plugs Ø length 1 4 x 2 6 mm x 50 mm 5 16 x 1 9 16 8 mm x 40 mm Machine must be bolted to the base or floor Fittings are supplied with machine Fixing materials fo...

Reviews: