background image

13/16"

40 3/16"

UG 13 1/4"

UO 12"

12 5/8"

13/16"

39 3/8"

27 1/4"

43 5/16"

27"

17 5/16"

22 1/16"

3 15/16"

2 13/16"

21 5/8"

2 13/16"

10 13/16"

1 1/2"

3/8"

2"

1/2"

2 9/16"

24 9/16"

12 1/4"

43 5/16"

27"  /  UO 26 7/8"

27 1/4"  /  UO 26 3/4"

17 3/8"

24 11/16"

PW 6080 EL - measurements in inches

6

Summary of Contents for PW 6080 EL

Page 1: ...36 15 M Nr 10 181 930 01 Installation Plan Washer extractor PW 6080 EL Electrically Heated en US ...

Page 2: ...usa com Technical Service Support Nationwide Phone 800 991 9380 Fax 800 220 1348 proservice mieleusa com 800 991 9380 609 419 4241 It is essential to read the operating and installation instructions before installing commissioning or using the machine This avoids the risk of accidents or damage All rights reserved ...

Page 3: ...1 4 UO 12 14 9 16 15 3 16 28 3 8 27 3 16 17 5 16 28 5 8 43 5 16 UG 13 1 4 52 3 16 40 3 16 UO 12 12 13 16 19 1 2 27 9 16 27 1 4 2 2 40 3 16 15 3 16 14 9 16 27 1 4 43 5 16 28 3 8 27 9 16 27 3 16 28 5 8 PW 6080 EL measurements in inches 3 ...

Page 4: ... 3 15 16 39 3 8 51 3 16 UG 13 1 4 UO 12 51 3 16 39 3 8 35 7 16 UG 13 1 4 UO 12 3 15 16 23 5 16 19 3 8 3 15 16 51 3 16 51 3 16 39 3 8 35 7 16 39 3 8 5 3 8 Version with drain pump LP PW 6080 EL measurements in inches 4 ...

Page 5: ...3 8 51 3 16 UG 13 1 4 UO 12 51 3 16 3 3 8 1 9 16 31 11 16 UG 13 1 4 UO 12 3 15 16 23 5 16 19 3 8 3 15 16 51 3 16 51 3 16 39 3 8 5 3 8 3 3 8 3 3 8 1 9 16 31 11 16 23 5 16 Version with drain valve AV PW 6080 EL measurements in inches 5 ...

Page 6: ...O 12 12 5 8 13 16 39 3 8 27 1 4 43 5 16 27 17 5 16 22 1 16 3 15 16 2 13 16 21 5 8 2 13 16 10 13 16 1 1 2 3 8 2 1 2 2 9 16 24 9 16 12 1 4 43 5 16 27 UO 26 7 8 27 1 4 UO 26 3 4 17 3 8 24 11 16 PW 6080 EL measurements in inches 6 ...

Page 7: ... 3 16 40 3 16 13 16 27 1 4 39 3 8 3 15 16 2 13 16 2 13 16 21 5 8 10 13 16 43 5 16 27 3 16 43 5 16 27 9 16 17 5 16 22 1 16 3 15 16 3 3 10 13 16 21 5 8 27 9 16 1 9 16 2 3 8 3 8 2 1 9 16 PW 6080 EL measurements in inches 7 ...

Page 8: ...PW 6080 EL measurements in millimeters 8 ...

Page 9: ... Version with drain pump LP PW 6080 EL measurements in millimeters 9 ...

Page 10: ...Version with drain valve AV PW 6080 EL measurements in millimeters 10 ...

Page 11: ...PW 6080 EL measurements in millimeters 11 ...

Page 12: ...PW 6080 EL measurements in millimeters 12 ...

Page 13: ...ured to floor Recommended height 11 13 16 300 mm Minimum height 2 3 4 70 mm Recommended width 27 9 16 700 mm Recommended depth 27 9 16 700 mm Dispensing pump External dispensing pumps 2 or 4 head pump Voltage external power supply required 120V Fusing 15A Supplied with supply cable and plug NEMA 5 15 Machine connections Electrical connection 1 Standard voltage 2 AC 220 240V 60Hz Voltage V 2 AC 220...

Page 14: ... Max pressure 145 psi 1000 kPa Max throughput 2 9 gal min 11 l min On site connection thread 3 4 garden hose thread male 3 4 garden hose thread male 61 1550 mm approx 18 5 gal hr approx 70 l hr Length of connection hose supplied 1 connection hose Hourly water demand average for 60 C program for stand ard connection with hot and cold water If hot water supply is not available connect hot water inle...

Page 15: ... 9 16 8 mm x 40 mm Base must be bolted to the floor Machine must be fixed to the base Fixing materials for a floating screed floor are to be provided on site Installation on floor or concrete base 2 clamps 2 screws DIN 571 Ø length 2 rawl plugs Ø length 1 4 x 2 6 mm x 50 mm 5 16 x 1 9 16 8 mm x 40 mm Machine must be bolted to the base or floor Fittings are supplied with machine Fixing materials fo...