Electrical connection
This machine is supplied with a
connection cable without a plug for
connection to a suitable connection
socket or isolator switch.
,
The voltage, rated load and fuse
rating are given on the data plate.
Please ensure these match the site
mains supply.
This machine must be connected to the
electricity supply in accordance with
local and national safety regulations.
Connection to the electricity supply
must only be carried out by a suitably
qualified and competent person.
Connection should be made via a
suitable connection socket or isolator
which complies with local and national
safety regulations and which is easily
accessible for disconnecting the
machine from the electrical supply.
Provision must be made on - site to
switch off all poles. Switches with a
minimum all-pole contact gap greater
than 3 mm are suitable for isolating the
machine. These include circuit
breakers, fuses and relays (IEC/EN
60947).
,
If the machine is disconnected
from the electricity supply, ensure
adequate measures are taken to
ensure that the machine cannot be
reconnected to the electricity supply
until all work has been carried out.
Should the connection cable require
replacing or changes be necessary in
the electrical installation, including
checking and/or replacing the fuse,
please make sure this is done by an
approved electrician to ensure
compliance with all local and national
electrical safety requirements.
For extra safety, it is advisable to
protect the machine with a suitable
residual current device (RCD) with a
trip current of 30 mA.
,
This machine can be converted
to a different voltage. Please
observe the switching instructions
given on the wiring diagram.
Conversion may only be carried out
by a Miele authorised service
technician or Miele technician.
If converted, the
heater rating
must
also be adapted.
,
The machine must be
permanently connected to the
electricity supply so that the door
can be opened. For this reason, it
must not be connected to devices
such as timers which would switch it
off automatically.
WARNING
THIS MACHINE MUST BE
EARTHED
Installation and connection
63
Summary of Contents for PW 5065
Page 66: ...66 ...
Page 76: ...Alteration rights reserved 4713 M Nr 09 756 190 00 ...