Fault messages in the display
Message in the display
Possible cause
Remedy
A
q
Drainage fault
– The water outlet is
blocked or restricted.
LP version: Clean the drain
filter and the drain pump.
AV version: Call the
Service Department.
– The drain hose has
been fixed too high.
The maximum drain height
is 1 m.
p
Water inlet fault
The water inlet is
blocked or restricted.
Check whether
– the stopcock is opened
wide enough.
– the inlet hose is kinked.
o
Waterproof system
has reacted
The water protection
system has reacted.
– Close the stopcock.
– Call the Service
Department.
,
Technical fault.
Call Service
There is a fault.
Start the programme
again.
If the fault message
appears again, contact the
Service Department.
,
Fault
Disinfection temp.
not
reached
During the disinfection
programme the water
temperature was not
reached.
The machine has
not
carried out the disinfection
cycle correctly.
Start the programme
again.
A
To switch off the fault message, press the
OK button.