The PG 8080 U / PG 8080i comes
equipped with a 14/3 AWG cord for
connection to a standard AC 120 V,
60 Hz power outlet with a NEMA 5-15P
plug.
If available, the dishwasher may be
connected to a 120/208-240V, 60Hz,
power supply. This will increase the
power to the heating elements and
shorten the time of selected wash
cycle.
120V 208-240V
Rated Load (kW) 1.5
3.9 - 4.2
Fuse Rating
15A
30A
To connect the machine to a
120/208-240V supply, the standard
power cord must be removed and
replaced by a 10/4 AWG cable of the
type: S, SE, SO, SOO, ST, STO or
STOO. A 3 pole, 4-wire grounding plug
and receptacle are recommended
(NEMA Type 14-30P).
The
conversion diagram
and
wiring
diagram
are secured to the inner side
of the toe kick.
Removing the toe kick
Disconnect the machine from the
mains electrical supply.
^
Remove the fixing screws from the
toe kick and take it off.
Power connection options
Electrical connection
66