Technical Information
48
T1500 Series Clothes Dryers
6. Remove the wire jumper from inside the drum.
7. Select “Timed Cycles Fluff” in the service mode and wait for approximately 60
seconds.
The “Cooling down” LED Illuminates
Circuit is In proper working order
The “Cooling down” and “Drying” LEDs
flash alternately
Circuit defective (Lifter bars
drum partially short-circuited.
Resistance is < 50 M.Ohms
8. Disconnect the wires to the drum and lifter bars at the pickup connection plug.
9. Select “Timed Cycles Fluff” in the service mode and wait for approximately 30
seconds.
The “Cooling down” LED Illuminates
Check circuit outside of the Control
Electronic. (e.g.~ slip rings, wiring, lifter
bars, sensor contacts etc).
The “Cooling down” and “Drying” LEDs
flash alternately
Replace the Control Electronic.