Warning and Safety instructions
10
Miele can only guarantee the safety of the appliance when genu-
ine original Miele replacement parts are used. Faulty components
must only be replaced by Miele spare parts.
The hob is not intended for use with an external timer switch or a
remote control system.
Connection to the gas supply must be carried out by a suitably
qualified gas fitter (e.g. a Gas Safe registered technician in the U.K).
The hob may be connected to the electrical supply by a fused plug
and switched socket. If you wish to connect it to a fused spur con-
nection, or if the plug has been removed or the connection cable is
not supplied with a plug, the hob must be connected to the mains
supply by a suitably qualified electrician.
If the connection cable is damaged, it must be replaced by a suit-
ably qualified electrician with a special connection cable of type H
05 VV-F (pvc insulated). See "Electrical connection".
During installation, maintenance and repair work, the hob must be
disconnected from the mains electricity supply. The gas supply must
also be shut off. Depending on country this is done in one of several
different ways:
– the mains fuse has been disconnected, or
– the screw-out fuse is removed (in countries where this is applic-
able), or
– switch off at the wall socket and withdraw the plug from the
socket. Pull by the plug and not by the mains connection cable to
disconnect from the mains electricity supply.
– the gas inlet valve is closed.