Converting to another gas type
55
Conversion from one type of gas
to another, should only be under-
taken by an approved and registered
gas installer in strict accordance with
current local and national safety and
building regulations.
Disconnect the hob from the electri-
city supply and turn off the gas sup-
ply.
When converting to another type of
gas, both the main
and
small jets
need to be changed.
Jet table
The jet markings refer to a ¹/₁₀₀ mm
bore diameter.
Main jet
Small jet
Natural gas H
Small burner
Medium burner
Large burner
Wok burner
0.76
0.94
1.20
2x 1.00 / 0.72
0.39
0.42
0.54
0.88 / 0.42
Liquid gas
Small burner
Medium burner
Large burner
Wok burner
0.52
0.66
0.81
2x 0.66 / 0.46
0.23
0.27
0.39
0.52 / 0.23
Changing the jets
Disconnect the hob from the electri-
city supply and turn off the gas sup-
ply.
Changing the main jets
Small, medium and large burners
Remove the pan support, burner
cap
and burner head
.
Using an M7 socket spanner, un-
screw the main jet
Fit the correct jets securely (see jet
table).
Secure the jets against inadvertent
loosening with sealing wax.