Installation
*
I
N
S
T
A
L
L
A
T
I
O
N
*
42
Adjust the front feet with a ratchet (at-
tachment: socket, 8 mm) or a TX 20
screwdriver
.
Tip:
Proceed carefully when adjusting
the feet, alternating between the left
and right feet.
Place a spirit level across the installa-
tion aids
on the appliance door to
check the refrigeration appliance’s
alignment.
Unscrew the adjustable feet
and
on both sides at least until the
marking on the plinth has reached the
specified distance of 32 mm on the
spacer
. The standard dimension of
32 mm relates to a niche height of
2134 mm.
It is important to adjust the feet to a
height of at least 32 mm so that the
ventilation of the refrigeration appli-
ance via the plinth functions correctly.
Risk of damage if the feet are
adjusted too much.
The rear adjustable feet can be dam-
aged.
Unscrew the feet
only until
the
marking on the plinth is aligned to a
maximum of 62 mm (max. niche
height of 2164 mm).
Summary of Contents for K 2601 Vi
Page 30: ...Installation I N S T A L L A T I O N 30 K 2801 Vi K 2811 Vi 756 mm 2029 mm 102 132 mm ...
Page 31: ...Installation I N S T A L L A T I O N 31 K 2901 Vi K 2911 Vi 908 mm 2029 mm 102 132 mm ...
Page 114: ......
Page 116: ...M Nr 11 273 020 00 en GB K 2601 Vi K 2611 Vi K 2801 Vi K 2811 Vi K 2901 Vi K 2911 Vi ...