Important
If the exhaust ducting is to run
through rooms, ceiling space etc.,
where there may be great variations
in temperature between the different
areas, the problem of sweating or
condensation will need to be ad-
dressed.
The exhaust ducting will need to be
suitably insulated.
Condensate trap
In addition to insulating the exhaust
ducting we recommend that a suitable
condensate trap is also installed to col-
lect and evaporate any condensate
which may occur.
When installing a condensate trap en-
sure that it is positioned vertically and if
possible directly above the exhaust
socket.
Installation - extraction
31