All Gas Range dimensions

*INSTALLATION*

Front view of HR 1135-3 AG

(x) = Depending on the appliance height adjustment: 5"–6 1/2" 
(127 mm–165.1 mm)

38

Summary of Contents for HR 1134-3 AG

Page 1: ...Installation Instructions Range To prevent accidents and damage to the range you must read all instructions supplied before installing or using the appliance en US CA M Nr 11 918 390 ...

Page 2: ...t or tamper with the safety interlocks b Do not place any object between the oven front face and the door or allow soil or cleaner residue to accumulate on sealing surfaces c Do not operate the oven if it is damaged It is particularly important that the oven door close properly and that there is no damage to the 1 Door bent 2 hinges and latches broken or loosened 3 door seals and sealing surfaces ...

Page 3: ... moved the range slide the locking latch onto the anti tip device until you feel it lock into place Do not use the range if the anti tip device has not been properly installed and engaged Failure to observe the information contained in the installation instructions can lead to serious or fatal injuries for children and adults All ranges can tip Injury to persons could result Install anti tip devic...

Page 4: ...t touch any electric switches Do not use any phones inside your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you are unable to reach your gas provider call the fire department Installation and service must be performed by a qualified installer qualified service agency or your gas provider In Massachusetts installation must be perform...

Page 5: ...2 Ventilation 22 Range net weight 23 Required connections 23 All Gas Range dimensions 24 HR 1124 3 AG 24 Detailed views of HR 1124 3 AG 26 HR 1134 3 AG HR 1135 3 AG HR 1136 3 AG 30 Detailed views of HR 1134 3 AG 32 Detailed views of HR 1135 3 AG 36 Detailed views of HR 1136 3 AG 40 All Electric Range dimensions 44 Detailed views of HR 1421 3 E 46 Detailed views of HR 1622 3 i 50 Dual Fuel Range di...

Page 6: ...rical connection 104 Data plate 106 Gas connection 107 Burner ratings 109 Burner ratings HR 1124 3 AG 109 Burner ratings HR 1134 3 AG 110 Burner ratings HR 1135 3 AG 110 Burner ratings HR 1136 3 AG 111 Burner ratings HR 1724 3 DF 112 Burner ratings HR 1924 3 DF 112 Burner ratings HR 1934 3 DF 113 Burner ratings HR 1935 3 DF 113 Burner ratings HR 1936 3 DF 114 Burner ratings HR 1954 3 DF 115 Burner...

Page 7: ...ion instructions carefully before installing and connecting the appliance Read the operating instructions before using the range for the first time To prevent accidents and damage to the appliance always observe both the installation instructions and operating instructions Both documents contain important information about installation safety use and maintenance Miele cannot be held liable for dam...

Page 8: ...r its intended purpose Keep these operating instructions in a safe place and pass them on to any future user Read and follow the specific PRECAUTIONS TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY found at the beginning of this manual Only use the appliance for its intended purpose Install or locate this appliance only in accordance with the provided installation instructions and all loc...

Page 9: ... must be kept away from the range unless they are constantly supervised Risk of burns due to improper use Do not allow children to operate the range Burn Hazard Do not allow children to use the oven Failure to do so can result in severe burns or serious injury Burn Hazard Do not allow children to use the cooktop Failure to do so can result in severe burns or serious injury Risk of suffocation from...

Page 10: ...d so children cannot pull them down and be burned Risk of injury from the open door The oven door can support a maximum weight of 33 lbs 15 kg Children could injure themselves on an open door Do not let children sit on the door lean against it or swing on it Technical safety This appliance must be installed and connected in compliance with the installation instructions Unauthorized installation ma...

Page 11: ...g latch into place on the anti tip device The locking latch must be noticeably engaged with the bolt of the anti tip bracket A damaged range can be dangerous Always check for visible signs of damage Never use a damaged appliance The electrical safety of the range can only be guaranteed when it is properly grounded Compliance with this essential safety requirement is absolutely mandatory If in any ...

Page 12: ...ese are a fire hazard and do not guarantee the required level of appliance safety This range must not be installed and operated in non stationary installations e g on a ship Risk of injury due to electric shock Any contact with live connections or tampering with the electrical or mechanical components of the range will endanger your safety and may lead to appliance malfunctions Do not open the ran...

Page 13: ...at extends at least 4 3 4 12 cm past the bottom of the cabinets For safety reasons only use the range when it has been fully installed The water shut off valves must be accessible when the appliance is installed The protective sleeve of the water intake hose must not be damaged or become kinked The integrated water protection system offers protection from water damage provided the following condit...

Page 14: ...brushes or sharp metal tools to clean the door glass Try to prevent the interior walls being splashed with food containing salt If this does happen wipe it away thoroughly to avoid corrosion to stainless steel surfaces inside the oven compartment The side runners can be removed see Cleaning and care of the oven Removing the side runners Reinstall the side runners correctly Coarse soiling in the ov...

Page 15: ... very high temperatures Do not use the probe when using the broiling operating modes Do not store the probe in the oven compartment when it is not being used Accessories that are not suitable for the Self Clean program will be damaged by the high temperatures Remove all accessories that are not suitable for the Self Clean program from the oven compartment before starting the Self Clean process Thi...

Page 16: ...d manufacturer If there is more than one appliance installed below the range hood each with a different safety clearance the largest clearance must be used Scope of delivery Toe kick panel and splash guard 30 and 36 Range These components are located in the packaging of the Range 48 Range These components are pre assembled Installation of the toe kick The toe kick has sheet metal lugs and magnets ...

Page 17: ...efully and place it securely on a soft surface so that it lies flat Remove the grill from the cooktop Remove the protective panel and if required the frame Clean the parts with warm water liquid dish soap and a soft sponge Dry all parts with a soft cloth Reinstall by following these instructions in reverse order Place the frame on the surface burner The recess for the igniter is located on the rig...

Page 18: ...rd is available in the following heights 12 305 mm and 20 508 mm All Gas Range Risk of injury caused by hot vapors Hot vapors are emitted above the island trim during Self Clean as well as when cooking food in the oven You could burn yourself on the hot vapors Do not reach above the island trim and keep others away from it when you are using the oven All Gas Range Hot vapors are emitted above the ...

Page 19: ...n be removed 1 2 2 a Extender b Air duct Insert one extender onto each of the left and right air ducts Screw the extenders into place with 2 screws each 1 2 3 a Backguard b Rear backguard panel c Interior panel To avoid scratching the backguard place it front side downward on a soft surface e g a blanket The lower edge should line up with the edge of the table so that the backguard is lying flat R...

Page 20: ...air duct extenders from above As soon as the backguard is sitting on the Range push the backguard backward Secure the interior panel and the rear panel to the backguard with the screws supplied Secure the backguard to the Range with the screws supplied Backguard 12 305 mm Backguard 20 508 mm ...

Page 21: ...anti tip device and connecting the Range Undo the screws from the island trim Pull back the island trim slightly until it can be removed Reinstall the backguard by following these instructions in reverse order RBS Backsplash The backsplash is intended for installation to a Miele Range Hood DAR model Observe the installation instructions of the Miele Range Hood ...

Page 22: ...e flat level and made of a strong rigid material The niche floor must be made of strong rigid material Because the Range is heavy and has to be secured with the anti tip device supplied the surface must be able to fully bear the load of the appliance If necessary seek the advice of an architect or construction expert Do not carry or lift the range by the oven door handle or the control panel Venti...

Page 23: ... 3 DF HR 192x 3 DF 29 15 16 762 mm approx 307 lbs 140 kg HR 113x 3 AG HR 193x 3 DF 35 15 16 915 mm approx 405 lbs 180 kg HR 195x 3 DF 47 15 16 1 220 mm approx 573 lbs 260 kg Required connections Model Electrical connection Gas connection Plumbed water connection HR 112x 3 AG HR 113x 3 AG Yes Yes No HR 1421 3 E Yes No No HR 1622 3 i Yes No Yes HR 172x 3 DF Yes Yes No HR 192x 3 DF HR 193x 3 DF HR 19...

Page 24: ...connections E Electrical connection G Gas connection No Dimensions Description 13 330 mm Maximum depth of upper cabinet 18 457 mm Minimum safety distance to bottom edge of upper cabinet 35 1 2 37 901 940 mm Distance from the floor to cooktop surface 10 254 mm Minimum safety distance to combustible surfaces 24 ...

Page 25: ...e Ventilation Hood Appliance dimensions Distance between cooktop and ventilation hood S For all other ventilation hoods please consult the manufacturer s specifications for required distances approx 10 1 16 256 mm Maximum connection width right and left Position of the wall socket approx 4 1 2 115 mm Maximum connection height approx 2 13 16 72 mm Maximum connection depth Please observe a minimum s...

Page 26: ...All Gas Range dimensions INSTALLATION Detailed views of HR 1124 3 AG Side view of HR 1124 3 AG x Depending on the appliance height adjustment 5 6 1 2 127 mm 165 1 mm 26 ...

Page 27: ...All Gas Range dimensions INSTALLATION Detailed front side view of HR 1124 3 AG 27 ...

Page 28: ...All Gas Range dimensions INSTALLATION Front view of HR 1124 3 AG x Depending on the appliance height adjustment 5 6 1 2 127 mm 165 1 mm 28 ...

Page 29: ...All Gas Range dimensions INSTALLATION Rear view of HR 1124 3 AG G E Electrical connection G Gas connection 29 ...

Page 30: ...area for the connections E Electrical connection G Gas connection No Dimensions Description 13 330 mm Maximum depth of upper cabinet 18 457 mm Minimum safety distance to bottom edge of upper cabinet 35 1 2 37 901 940 mm Distance from the floor to cooktop surface 10 254 mm Minimum safety distance to combustible surfaces 30 ...

Page 31: ... Ventilation Hood Appliance dimensions Distance between cooktop and ventilation hood S For all other ventilation hoods please consult the manufacturer s specifications for required distances approx 13 1 16 332 5 mm Maximum connection width right and left Position of the wall socket approx 4 1 2 115 mm Maximum connection height approx 2 13 16 72 mm Maximum connection depth Please observe a minimum ...

Page 32: ...All Gas Range dimensions INSTALLATION Detailed views of HR 1134 3 AG Side view of HR 1134 3 AG x Depending on the appliance height adjustment 5 6 1 2 127 mm 165 1 mm 32 ...

Page 33: ...All Gas Range dimensions INSTALLATION Detailed front side view of HR 1134 3 AG 33 ...

Page 34: ...All Gas Range dimensions INSTALLATION Front view of HR 1134 3 AG x Depending on the appliance height adjustment 5 6 1 2 127 mm 165 1 mm 34 ...

Page 35: ...All Gas Range dimensions INSTALLATION Rear view of HR 1134 3 AG E Electrical connection G Gas connection 35 ...

Page 36: ...All Gas Range dimensions INSTALLATION Detailed views of HR 1135 3 AG Side view of HR 1135 3 AG x Depending on the appliance height adjustment 5 6 1 2 127 mm 165 1 mm 36 ...

Page 37: ...All Gas Range dimensions INSTALLATION Detailed front side view of HR 1135 3 AG 37 ...

Page 38: ...All Gas Range dimensions INSTALLATION Front view of HR 1135 3 AG x Depending on the appliance height adjustment 5 6 1 2 127 mm 165 1 mm 38 ...

Page 39: ...All Gas Range dimensions INSTALLATION Rear view of HR 1135 3 AG E Electrical connection G Gas connection 39 ...

Page 40: ...All Gas Range dimensions INSTALLATION Detailed views of HR 1136 3 AG Side view of HR 1136 3 AG x Depending on the appliance height adjustment 5 6 1 2 127 mm 165 1 mm 40 ...

Page 41: ...All Gas Range dimensions INSTALLATION Detailed front side view of HR 1136 3 AG 41 ...

Page 42: ...All Gas Range dimensions INSTALLATION Front view of HR 1136 3 AG x Depending on the appliance height adjustment 5 6 1 2 127 mm 165 1 mm 42 ...

Page 43: ...All Gas Range dimensions INSTALLATION Rear view of HR 1136 3 AG E Electrical connection G Gas connection 43 ...

Page 44: ...nge dimensions INSTALLATION HR 1421 3 E HR 1622 3 i The shaded area represents the installation area for the connections E Electrical connection W Plumbed water connection HR 1622 3 i only Only available in Canada 44 ...

Page 45: ...e surface or when a Miele Ventilation Hood is installed For all other ventilation hoods please consult the manufacturer s specifications for required distances approx 10 1 16 256 mm Maximum connection width right and left Position of the wall socket approx 4 1 2 115 mm Maximum connection height approx 2 13 16 72 mm Maximum connection depth Please observe a minimum safety distance of at least 12 30...

Page 46: ...All Electric Range dimensions INSTALLATION Detailed views of HR 1421 3 E Side view of HR 1421 3 E x Depending on the appliance height adjustment 5 6 1 2 127 mm 165 1 mm 46 ...

Page 47: ...All Electric Range dimensions INSTALLATION Detailed front side view of HR 1421 3 E 47 ...

Page 48: ...All Electric Range dimensions INSTALLATION Front view of HR 1421 3 E x Depending on the appliance height adjustment 5 6 1 2 127 mm 165 1 mm 48 ...

Page 49: ...All Electric Range dimensions INSTALLATION Rear view of HR 1421 3 E E Electrical connection 49 ...

Page 50: ...All Electric Range dimensions INSTALLATION Detailed views of HR 1622 3 i Side view of HR 1622 3 i x Depending on the appliance height adjustment 5 6 1 2 127 mm 165 1 mm 50 ...

Page 51: ...All Electric Range dimensions INSTALLATION Detailed front side view of HR 1622 3 i 51 ...

Page 52: ...All Electric Range dimensions INSTALLATION Front view of HR 1622 3 i x Depending on the appliance height adjustment 5 6 1 2 127 mm 165 1 mm 52 ...

Page 53: ...All Electric Range dimensions INSTALLATION Rear view of HR 1622 3 i E Electrical connection W Plumbed water connection 53 ...

Page 54: ... connections E Electrical connection G Gas connection No Dimensions Description 13 330 mm Maximum depth of upper cabinet 18 457 mm Minimum safety distance to bottom edge of upper cabinet 35 1 2 37 901 940 mm Distance from the floor to cooktop surface 10 254 mm Minimum safety distance to combustible surfaces 54 ...

Page 55: ...le Ventilation Hood Appliance dimensions Distance between cooktop and ventilation hood S For all other ventilation hoods please consult the manufacturer s specifications for required distances approx 10 1 16 256 mm Maximum connection width right and left Position of the wall socket approx 4 1 2 115 mm Maximum connection height approx 2 13 16 72 mm Maximum connection depth Please observe a minimum ...

Page 56: ...Dual Fuel Range dimensions INSTALLATION Detailed views of HR 1724 3 DF Side view of HR 1724 3 DF x Depending on the appliance height adjustment 5 6 1 2 127 mm 165 1 mm 56 ...

Page 57: ...Dual Fuel Range dimensions INSTALLATION Detailed front side view of HR 1724 3 DF 57 ...

Page 58: ...Dual Fuel Range dimensions INSTALLATION Front view of HR 1724 3 DF x Depending on the appliance height adjustment 5 6 1 2 127 mm 165 1 mm 58 ...

Page 59: ...Dual Fuel Range dimensions INSTALLATION Rear view of HR 1724 3 DF G E Electrical connection G Gas connection 59 ...

Page 60: ... Electrical connection W Plumbed water connection G Gas connection No Dimensions Description 13 330 mm Maximum depth of upper cabinet 18 457 mm Minimum safety distance to bottom edge of upper cabinet 35 1 2 37 901 940 mm Distance from the floor to cooktop surface 10 254 mm Minimum safety distance to combustible surfaces 60 ...

Page 61: ...le Ventilation Hood Appliance dimensions Distance between cooktop and ventilation hood S For all other ventilation hoods please consult the manufacturer s specifications for required distances approx 10 1 16 256 mm Maximum connection width right and left Position of the wall socket approx 4 1 2 115 mm Maximum connection height approx 2 13 16 72 mm Maximum connection depth Please observe a minimum ...

Page 62: ...Dual Fuel Range dimensions INSTALLATION Detailed views of HR 1924 3 DF Side view of HR 1924 3 DF x Depending on the appliance height adjustment 5 6 1 2 127 mm 165 1 mm 62 ...

Page 63: ...Dual Fuel Range dimensions INSTALLATION Detailed front side view of HR 1924 3 DF 63 ...

Page 64: ...Dual Fuel Range dimensions INSTALLATION Front view of HR 1924 3 DF x Depending on the appliance height adjustment 5 6 1 2 127 mm 165 1 mm 64 ...

Page 65: ...Dual Fuel Range dimensions INSTALLATION Rear view of HR 1924 3 DF E Electrical connection W Plumbed water connection G Gas connection 65 ...

Page 66: ...connections E Electrical connection W Plumbed water connection G Gas connection No Dimensions Description 13 330 mm Maximum depth of upper cabinet 18 457 mm Minimum safety distance to bottom edge of upper cabinet 35 1 2 37 901 940 mm Distance from the floor to cooktop surface 10 254 mm Minimum safety distance to combustible surfaces 66 ...

Page 67: ...el with DRxB XXL blower Refer to the installation instructions for the Miele Ventilation Hood Appliance dimensions Distance between cooktop and ventilation hood S For all other ventilation hoods please consult the manufacturer s specifications for required distances approx 13 1 16 332 5 mm Maximum connection width right and left Position of the wall socket approx 4 1 2 115 mm Maximum connection he...

Page 68: ... for the Miele Ventilation Hood Appliance dimensions Distance between cooktop and ventilation hood S For all other ventilation hoods please consult the manufacturer s specifications for required distances approx 13 1 16 332 5 mm Maximum connection width right and left Position of the wall socket approx 4 1 2 115 mm Maximum connection height approx 2 13 16 72 mm Maximum connection depth Please obse...

Page 69: ...Dual Fuel Range dimensions INSTALLATION Detailed views of HR 1934 3 DF Side view of HR 1934 3 DF x Depending on the appliance height adjustment 5 6 1 2 127 mm 165 1 mm 69 ...

Page 70: ...Dual Fuel Range dimensions INSTALLATION Detailed front side view of HR 1934 3 DF 70 ...

Page 71: ...Dual Fuel Range dimensions INSTALLATION Front view of HR 1934 3 DF x Depending on the appliance height adjustment 5 6 1 2 127 mm 165 1 mm 71 ...

Page 72: ...Dual Fuel Range dimensions INSTALLATION Rear view of HR 1934 3 DF E Electrical connection W Plumbed water connection G Gas connection 72 ...

Page 73: ...Dual Fuel Range dimensions INSTALLATION Detailed views of HR 1935 3 DF Side view of HR 1935 3 DF x Depending on the appliance height adjustment 5 6 1 2 127 mm 165 1 mm 73 ...

Page 74: ...Dual Fuel Range dimensions INSTALLATION Detailed front side view of HR 1935 3 DF 74 ...

Page 75: ...Dual Fuel Range dimensions INSTALLATION Front view of HR 1935 3 DF x Depending on the appliance height adjustment 5 6 1 2 127 mm 165 1 mm 75 ...

Page 76: ...Dual Fuel Range dimensions INSTALLATION Rear view of HR 1935 3 DF E Electrical connection W Plumbed water connection G Gas connection 76 ...

Page 77: ...Dual Fuel Range dimensions INSTALLATION Detailed views of HR 1936 3 DF Side view of HR 1936 3 DF x Depending on the appliance height adjustment 5 6 1 2 127 mm 165 1 mm 77 ...

Page 78: ...Dual Fuel Range dimensions INSTALLATION Detailed front side view of HR 1936 3 DF 78 ...

Page 79: ...Dual Fuel Range dimensions INSTALLATION Front view of HR 1936 3 DF x Depending on the appliance height adjustment 5 6 1 2 127 mm 165 1 mm 79 ...

Page 80: ...Dual Fuel Range dimensions INSTALLATION Rear view of HR 1936 3 DF E Electrical connection W Plumbed water connection G Gas connection 80 ...

Page 81: ...connections E Electrical connection W Plumbed water connection G Gas connection No Dimensions Description 13 330 mm Maximum depth of upper cabinet 18 457 mm Minimum safety distance to bottom edge of upper cabinet 35 1 2 37 901 940 mm Distance from the floor to cooktop surface 10 254 mm Minimum safety distance to combustible surfaces 81 ...

Page 82: ...Miele Ventilation Hood Appliance dimensions Distance between cooktop and ventilation hood S For all other ventilation hoods please consult the manufacturer s specifications for required distances approx 19 1 8 485 mm Maximum connection width right and left Position of the wall socket approx 3 1 2 90 mm Maximum connection height approx 2 13 16 72 mm Maximum connection depth Please observe a minimum...

Page 83: ...d DAR model with DRxB XXL blower Refer to the installation instructions for the Miele Ventilation Hood Appliance dimensions Distance between cooktop and ventilation hood S For all other ventilation hoods please consult the manufacturer s specifications for required distances approx 19 1 8 485 mm Maximum connection width right and left Position of the wall socket approx 3 1 2 90 mm Maximum connecti...

Page 84: ...Dual Fuel Range dimensions INSTALLATION Detailed views of HR 1954 3 DF Side view of HR 1954 3 DF x Depending on the appliance height adjustment 4 5 1 2 101 6 mm 139 7 mm 84 ...

Page 85: ...Dual Fuel Range dimensions INSTALLATION Detailed front side view of HR 1954 3 DF 85 ...

Page 86: ...Dual Fuel Range dimensions INSTALLATION Front view of HR 1954 3 DF x Depending on the appliance height adjustment 4 5 1 2 101 6 mm 139 7 mm 86 ...

Page 87: ...Dual Fuel Range dimensions INSTALLATION Rear view of HR 1954 3 DF E Electrical connection W Plumbed water connection G Gas connection 87 ...

Page 88: ...Dual Fuel Range dimensions INSTALLATION Detailed views of HR 1955 3 DF Side view of HR 1955 3 DF x Depending on the appliance height adjustment 4 5 1 2 101 6 mm 139 7 mm 88 ...

Page 89: ...Dual Fuel Range dimensions INSTALLATION Detailed front side view of HR 1955 3 DF 89 ...

Page 90: ...Dual Fuel Range dimensions INSTALLATION Front view of HR 1955 3 DF x Depending on the appliance height adjustment 4 5 1 2 101 6 mm 139 7 mm 90 ...

Page 91: ...Dual Fuel Range dimensions INSTALLATION Rear view of HR 1955 3 DF E Electrical connection W Plumbed water connection G Gas connection 91 ...

Page 92: ...Dual Fuel Range dimensions INSTALLATION Detailed views of HR 1956 3 DF Side view of HR 1956 3 DF x Depending on the appliance height adjustment 4 5 1 2 101 6 mm 139 7 mm 92 ...

Page 93: ...Dual Fuel Range dimensions INSTALLATION Detailed front side view of HR 1956 3 DF 93 ...

Page 94: ...Dual Fuel Range dimensions INSTALLATION Front view of HR 1956 3 DF x Depending on the appliance height adjustment 4 5 1 2 101 6 mm 139 7 mm 94 ...

Page 95: ...Dual Fuel Range dimensions INSTALLATION Rear view of HR 1956 3 DF E Electrical connection W Plumbed water connection G Gas connection 95 ...

Page 96: ... or wall and engage with the center of the bottom of the range Do not use the range if the anti tip device has not been properly installed and engaged Due to the size and weight of the appliance installation should be carried out by two people Any opening in the wall behind the appliance and in the floor under the appliance shall be sealed We recommend removing the oven door before installing the ...

Page 97: ...has distance A to the supporting wall due to unevenness or wall covering e g tile level you must install the anti tip device to the supporting floor Alternatively you can also install the anti tip device with an adapter between the supporting wall and the anti tip device The adapter must compensate dimension A and be made of suitable material so that a supporting connection is made between the wal...

Page 98: ...e sure that you do not damage any wires or pipes when drilling holes to attach the anti tip device Check the position of the electrical gas and plumbed water connections see Electrical connection Gas Connection and Plumbed water connection An overview of electrical and gas connections required for your Range can be found in Notes on installation 98 ...

Page 99: ... mm Only available in Canada Installing the Range with the anti tip device Wear safety shoes and gloves The anti tip device should be installed at the bottom rear of the Range at the midpoint of the width Measure the installation space for the Range close to floor level Mark the wall at the middle of the space width Position the notch of the anti tip device on the wall marking The anti tip device ...

Page 100: ...r section of the locking latch This slot engages with the bolt of the anti tip device when you slide the locking latch into the Range Complete all necessary connections for the Range Read the information in the Electrical connection Gas connection and Plumbed water connection sections The Range can be damaged if it is lifted using the panel the island trim or the door handle Open the oven door and...

Page 101: ...red for the Range a Opening in the Range housing b Anti tip device bolt c Locking clamp with slot The toe kick panel can only be attached if the locking clamp has been slid all the way into the appliance Secure the toe kick panel onto the Range Disconnecting the range from the anti tip device WARNING Children and adults can tip over the range if has not been secured This may lead to fatal injuries...

Page 102: ...nly be connected to a cold water supply The appliance is constructed to comply with the relevant local and national safety standards and may be connected to the water supply without a non return valve if national regulations permit The water connection pressure needs to be between 14 5 and 145 psi 1 and 10 bar If the pressure is higher than this install a pressure reducing valve 30 and 36 range Th...

Page 103: ... the power supply before connecting it to the water supply Turn off the water supply at the faucet before connecting the appliance to the water supply Make sure that the faucet remains accessible after the appliance has been installed A faucet with a 3 8 connection thread is required for the connection Connect the stainless steel hose to the water supply Old or used hoses must not be connected to ...

Page 104: ...Installation repairs and other work by unqualified persons could be dangerous Miele cannot be held liable for unauthorized work Installation maintenance and repairs must only be carried out by a Miele authorized technician The connection data voltage and frequency on the data tag of the Range must match the domestic electrical supply in order to avoid the risk of damage to the Range Compare this d...

Page 105: ... V or 120 240 V 50 A 40 A 60 Hz Temporary or permanent operation on an autonomous power supply system or a power supply system that is not synchronized with the grid power supply e g island networks back up systems is possible A prerequisite for operation is that the power supply system complies with the specifications of EN 50160 or an equivalent standard The function and operation of the protect...

Page 106: ...is information available if you need to contact Miele so that any issues can be rectified as quickly as possible This appliance must be grounded in compliance with all applicable local and national regulations Installation repair and maintenance work should only be performed by a Miele authorized service technician in compliance with local regulations and the ANSI National Electrical Code NFPA 70 ...

Page 107: ...ction fittings on the Range do not come into contact with hot exhaust gases Flexible connection lines can be damaged by incorrect routing Attach flexible connection lines in such a way that they do not come into contact with any moving kitchen parts e g a drawer and are not exposed to mechanical stress The Range and the faucet must be disconnected from the gas supply during a gas pressure test Dis...

Page 108: ...e gas pressure may not undershoot or exceed certain values Make sure that the maximum gas pressure upstream of the gas pressure controller does not amount to more than 1 2 psi 3 5 kPA for natural gas NG and liquid propane LP Make sure that the minimum gas pressure amounts to a 6 water head in the case of natural gas and a 11 water head in the case of propane gas 1 2 NPT ...

Page 109: ... Browning burner 22 000 6 4 Bake burner 23 200 6 8 Total cooktop output 71 000 20 8 Maximum total output of Range 94 200 27 6 Liquid propane LP Btu hr kW Simmer burner 12 500 3 7 Power burner 19 500 5 7 Browning burner 20 150 5 9 Bake burner 23 200 6 8 Total cooktop output 71 000 20 8 Maximum total output of Range 94 200 27 6 109 ...

Page 110: ...e LP Btu hr kW Simmer burner 8 000 2 3 Power burner rear 9 000 2 6 Power burner front 19 500 5 7 Browning burner 20 150 5 9 Bake burner 27 500 8 1 Total cooktop output 84 500 24 8 Maximum total output of Range 112 000 32 8 Burner ratings HR 1135 3 AG Natural gas NG Btu hr kW Simmer burner 8 000 2 3 Power burner rear 9 000 2 6 Power burner front 19 500 5 7 Grill 19 000 5 6 Browning burner 22 000 6 ...

Page 111: ... Browning burner 22 000 6 4 Bake burner 25 500 7 5 Total cooktop output 69 000 20 2 Maximum total output of Range 94 500 27 7 Liquid propane LP Btu hr kW Simmer burner 8 000 2 3 Power burner rear 9 000 2 6 Power burner front 19 500 5 7 Griddle plate 14 300 4 2 Browning burner 20 150 5 9 Bake burner 27 500 8 1 Total cooktop output 70 300 20 6 Maximum total output of Range 97 800 28 7 111 ...

Page 112: ... 8 Liquid propane LP Btu hr kW Simmer burner 12 500 3 7 Power burner 19 500 5 7 Total cooktop output 71 000 20 8 Burner ratings HR 1924 3 DF Natural gas NG Btu hr kW Simmer burner 12 500 3 7 Power burner 19 500 5 7 Total cooktop output 71 000 20 8 Liquid propane LP Btu hr kW Simmer burner 12 500 3 7 Power burner 19 500 5 7 Total cooktop output 71 000 20 8 112 ...

Page 113: ...otal cooktop output 98 200 28 8 Liquid propane LP Btu hr kW Simmer burner 12 500 3 7 Power burner rear 13 000 3 8 Power burner front 19 500 5 7 Total cooktop output 97 000 28 4 Burner ratings HR 1935 3 DF Natural gas NG Btu hr kW Simmer burner 12 500 3 7 Power burner rear 13 600 4 0 Power burner front 19 500 5 7 Grill 19 000 5 6 Total cooktop output 84 100 24 6 113 ...

Page 114: ... 500 3 7 Power burner rear 13 600 4 0 Power burner front 19 500 5 7 Griddle plate 13 000 3 8 Total cooktop output 78 100 22 9 Liquid propane LP Btu hr kW Simmer burner 12 500 3 7 Power burner rear 13 000 3 8 Power burner front 19 500 5 7 Griddle plate 14 300 4 2 Total cooktop output 78 800 23 1 114 ...

Page 115: ...tal cooktop output 125 200 36 7 Liquid propane LP Btu hr kW Simmer burner 10 000 2 9 Power burner rear 13 000 3 8 Power burner front 19 500 5 7 Total cooktop output 124 000 36 3 Burner ratings HR 1955 3 DF Natural gas NG Btu hr kW Simmer burner 10 000 2 9 Power burner rear 13 600 4 0 Power burner front 19 500 5 7 Grill 19 000 5 6 Total cooktop output 111 100 32 6 115 ...

Page 116: ...000 2 9 Power burner rear 13 600 4 0 Power burner front 19 500 5 7 Griddle plate 13 000 3 8 Total cooktop output 105 100 30 8 Liquid propane LP Btu hr kW Simmer burner 10 000 2 9 Power burner rear 13 000 3 8 Power burner front 19 500 5 7 Griddle plate 14 300 4 2 Total cooktop output 105 800 31 0 116 ...

Page 117: ...tion can be found on the data plate Data plate The data plate is located behind the toe kick panel The toe kick panel is attached to the toe kick of the Range by magnets so it can be removed and put back again easily There you can find the model number serial number and the connection data voltage frequency maximum rated load for your Range Have this information available if you need to contact Mi...

Page 118: ...for the proper functioning and safe use of the equipment Handling these materials improperly by disposing of them in your household waste can be harmful to your health and the environment Therefore please do not dispose of your old appliance with regular household waste and follow local regulations on proper disposal Consult with local authorities dealers or Miele in order to dispose of and recycl...

Page 119: ...respected In addition the integrated communication module contains software components which are distributed under open source licensing terms You can access these open source components along with the associated copyright notices copies of the valid licensing terms and any additional information locally via IP using a web browser http s ip address Licenses The liability and warranty arrangements ...

Page 120: ......

Page 121: ......

Page 122: ......

Page 123: ...en contacting Customer Service Canada Importer Miele Limited Headquarters and Miele Centre Customer Support Phone 888 99 MIELE 64353 info mieleusa com 161 Four Valley Drive Vaughan ON L4K 4V8 www miele ca Customer Care Centre Phone customercare miele ca 800 565 6435 905 532 2272 International Headquarters Miele Cie KG Carl Miele Straße 29 33332 Gütersloh Germany ...

Page 124: ...r 11 918 390 00 en US CA HR 1421 3 E HR 1622 3 i HR 1124 3 AG HR 1134 3 AG HR 1135 3 AG HR 1136 3 AG HR 1724 3 DF HR 1924 3 DF HR 1934 3 DF HR 1935 3 DF HR 1936 3 DF HR 1954 3 DF HR 1955 3 DF HR 1956 3 DF ...

Reviews: