Novotronic Models
Technical Information
61
6.2.9 Fault Code F16
Cause
Identity lost, programmed model variant has been deleted
Remedy
Reprogram the model variant
6.2.10 Fault Code F17
Cause
The catalyser temperature sensor Pt 1000 is open-circuited or its
resistance is too great
Remedy
Replace the Pt 1000 sensor