Drainage
This machine is fitted with two drainage
hoses. One hose is designated for dirty
water; the other for water emitted by the
steam condenser.
The drainage system is fitted with a
non-return valve which prevents dirty
water from flowing back into the
machine via the drain hose.
^
The machine should preferably be
connected to a separate drainage
system on-site.
If separate drainage is not available,
contact your Miele application
specialist for professional advice.
The on-site drain connection point
should be sited between 0.3 m and 1
m above the lower edge of the
machine.
If it is lower than 0.3 m, lay the hose
in a curve at a height of at least
0.3 m.
The drainage system must be able to
take a minimum drainage flow of 16
l/min.
^
The drain hoses are approx. 1.4 m
long, flexible and have an internal
diameter of 22 mm. They must not be
shortened.
Hose clips are supplied for securing
them in position.
^
Longer drain hoses (up to 4 m long)
are available to order from the Miele
Spare Parts Dept.
^
The drainage system must not
exceed 4 metres.
See also the installation diagram
supplied.