Dispensing liquid cleaning agent via DOS 1
Setting the dosage concentration
The dosage concentration must be set exclusively for liquid cleaning agent.
Set it according to the manufacturer's recommendations or the official
standards required.
The dosage concentration must not be altered even if powder cleaning agent
is dispensed via the dispenser in the door.
Step
Display / Result
^
Press
3
until E02 appears.
E02
^
Turn the programme selector to
B
.
without DOS Module connected:
with DOS Module connected:
10
= 10 sec dosage duration
1.00
= 1.0 % dosage concentration
^
Press
4
repeatedly as necessary or
hold pressed in until the required value
appears in the display, e.g. 0.50.
0.50
The dosage duration/concentration
level has now been set.
Dosage concentration set:
Venting the dispensing system
The dispensing system must be vented if:
– the dosage concentration is being set for the first time
– the liquid cleaning agent container runs out and was not refilled in time
Step
Display / Result
^
Press
3
until E02 appears.
E02
^
Turn the programme selector to
A
.
d§1
^
Press
4
.
The dispensing system will be vented
automatically.
0
will appear in the
display when the venting process has
finished.
^
Exit from programming mode.
Then start the Pre-rinse
D
programme.
Any agents which are in the wash
cabinet after the venting process will
be diluted before being drained away.