Total power rating
See data plate
Connection data
The connection data is quoted on the
data plate. Please ensure these match
the household mains supply.
Residual current device
For extra safety, it is advisable to pro-
tect the steam oven with a suitable re-
sidual current device (RCD) with a trip
range of 30 mA.
Replacing the mains connection
cable
When replacing the mains connection
cable, please use cable type H 05 VV-F
with a suitable cross-section. These
cables are available from the manufac-
turer or from Miele Service.
Disconnecting from the mains
Risk of electric shock from mains
voltage.
There is a risk of electric shock if the
appliance is reconnected to the
mains supply during repair or service
work.
After disconnection, ensure the ap-
pliance cannot be switched back on
by mistake.
To disconnect the appliance from the
mains power supply, do one of the fol-
lowing depending on installation:
Safety fuses
Completely remove the fuse links
from the screw caps.
Automatic circuit breakers
Press the test button (red) until the
middle button (black) springs out.
Built-in circuit breakers
For circuit breakers of at least type B
or C, switch the lever from 1 (on) to 0
(off).
Residual current device (RCD)
Residual current device: switch the
main switch from 1 (on) to 0 (off) or
press the test button.