Cleaning and care
When removing the filters for clean-
ing also clean off any residues of oil
or fat from the filter housing to pre-
vent the risk of these catching fire.
DA 272 i, DA 292 i only:
Put the filters back together.
When re-inserting the filters ensure
that the locking device faces down
towards the hob.
If a filter is inadvertently replaced the
wrong way round, use a small screw-
driver blade to unlock the filter
through the slots.
Changing the light tube and/or starter
Before any cleaning or maintenance
work the cooker hood must be dis-
connected from the mains supply
by
– switching it off at the wall socket
and removing the plug (do not pull
on the cable, only on the plug), or
– the mains fuse is withdrawn, or
– the screw-out fuse is removed, (in
countries where this is applicable).
Unscrew the fixing screws at the left
and right hand side. Whilst doing so
hold the light cover securely and
then take it out.
Release the light tube and the starter
by turning them and then lifting them
out of their holders.
Replace the fluorescent tube or star-
ter.
Cleaning and care