Retaining plate A
Drill a hole
b
8 mm Ø above the
worktop at a distance of
s
+
425 mm
.
Drill another hole
c
8 mm Ø
325 mm
underneath the first hole
b
.
Press S8 plugs into the drilled holes.
Screw on the retaining plate using
5 x 40 mm screws and adjust.
Drill 4 more holes
d
8 mm Ø through
the now mounted retaining plate and
press S8 plugs into the holes.
Screw in 4 screws 5 x 40 mm into
the plugs.
Drill 2 holes
h
8 mm Ø to be used
later to secure the vapour guide and
press S8 plugs into the drilled holes.
Retaining plate B
Address the top retaining plate B
flush to the room ceiling and mark
the positions on the wall of the 4
bore holes
e
to be drilled.
With a 6 mm Ø bit drill the 4 holes in
the wall and then press the S6 plugs
in the holes.
Screw in the top retaining plate with
4 screws 4 x 30 mm and 4.3 under-
lying washers.
If the measurement
y
from the top edge
of the hood to the ceiling is greater
than measurement
z
, it will be necess-
ary to fit retaining plate C for the tele-
scopic extension piece (see chart).
Hold the plate C in place so that the
distance between the ceiling and
bottom edge of the plate is
z
and
mark the positions for the 2 holes
f
to be drilled.
Installation
24
Summary of Contents for DA 206
Page 35: ...35 ...