Recirculation connection
If the site conditions are not suitable for
the cooker hood to be used for air ex-
traction, the appliance must be con-
nected for recirculation.
Push the directional unit on to the
top retaining plate.
Secure the flexible hose with the
hose clips to the directional unit and
to the exhaust socket of the motor
unit.
Active charcoal filters are available
from the Miele Spare Parts Depart-
ment or some Miele dealers.
Set the operating hours counter for
the active charcoal filter (see section
on Altering the filter operating hours
counter - Active charcoal filter)
Extension piece
An extension piece allows the cooker
hood to be fitted at varying distances
from the ceiling (see section on Ap-
pliance dimensions).
The extension piece has openings at
each side. These are for use when the
appliance is being used for recircula-
tion.
Recirculation
Extraction
For recirculation, the extension piece is
fitted with the openings at the top.
For extraction, the openings are not re-
quired. In this case the extension
piece is fitted with the openings at the
bottom. They are then covered by the
tower shaft.
Installation
29