Extraction connection
Only use narrower diameter pipe-
work where it is unavoidable, for
example where existing pipework
has to be used. The narrower the
diameter the lower the performance
and the noiser the operation.
Extraction connection should only
be carried out by a competent per-
son in accordance with building
regulations.
For extraction connection the flexible
hose is to be secured with a hose
clip to the vent socket of the motor.
The top end is led to the open air
through the wall or ceiling cut-out.
Proceed with the further steps for ex-
traction connection. (See section on
Connection for air extraction).
Important
If the exhaust ducting is to run through
rooms, ceiling space etc. where there
may be great variations in temperature
between the different areas, the prob-
lem of sweating or condensation will
need to be addressed.
The exhaust ducting will need to be
suitably insulated.
In addition to insulating the exhaust
ducting we recommend that a suitable
condensate trap is also installed to col-
lect and evaporate any condensate
which may occur.
Condensate traps are available from
the Miele Spare Parts Department.
When installing a condensate trap
ensure that it is positioned vertically
and if possible directly above the
exhaust connection.
Installation
28