Installation
*INSTALLATION*
73
E-box
a
Mains connection cable
b
Connection to window contact
c
Connection socket for the fan power
cable
d
Connection socket for the fan
control cable
e
Connection socket for the control
unit cable
Connection to window contact, if
required
The window contact is
connected to the mains voltage.
Danger of electric shock!
Disconnect the downdraft extractor
from the mains electricity supply
before connecting the switching
system.
The connection cable of the
switching system must only be
connected by a suitably qualified and
competent electrician.
The connection cable of the
switching system must be of the
correct type and cross-sectional area
in strict accordance with current
national and local safety regulations
and must not exceed 2.0 m in length.
The switching system must be
equipped with a potential-free
contact suitable for 230 V, 1 A. The
extractor is switched off when the
switch is open.
Only use suitable switching systems
(e.g. window contact switches,
pressure switches).
The switching system must be
suitable for use with inductive loads
(BLDC motor).
Use switching systems in strict
accordance with current national and
local safety regulations.
Summary of Contents for CSDA 7001 FL
Page 30: ...Installation INSTALLATION 30 Installation examples Recirculation mode Air extraction mode ...
Page 33: ...Installation INSTALLATION 33 Worktop cut out surface mounted B 500 1 ßR 4 B 10 0 10 1 1 ...
Page 40: ...Installation INSTALLATION 40 Front view ...
Page 41: ...Installation INSTALLATION 41 View from above ...
Page 60: ...Installation INSTALLATION 60 Air duct dimensions flush fit worktop depth 600 mm Side view ...
Page 62: ...Installation INSTALLATION 62 Front view ...
Page 63: ...Installation INSTALLATION 63 View from above ...
Page 77: ......
Page 78: ......