Warning and Safety instructions
10
Using at the same time as other heating appliances that depend on the air
from the room
Warning - danger of toxic fumes!
Great care should be taken when using the downdraft extractor at
the same time and in the same room or area of the house as
another heating appliance which depends on the air in the room.
Such appliances include gas, oil, wood or coal-fired boilers and
heaters, continuous flow or other water heaters, gas cooktops, or
ovens which draw air in from the room and duct exhaust gases out
through a chimney or extraction ducting.
When used in extraction mode, with or without an external motor
fitted, or in recirculation mode with a recirculation box installed
outside the room, the downdraft extractor draws air in from the
room in which it is installed and from neighbouring rooms.
If there is insufficient air, an underpressure will occur. The heating
appliance will be starved of oxygen, impairing combustion.
Harmful gases could be drawn out of the chimney or extraction
ducting back into the room, with potentially fatal consequences.
Summary of Contents for CSDA 7001 FL
Page 30: ...Installation INSTALLATION 30 Installation examples Recirculation mode Air extraction mode ...
Page 33: ...Installation INSTALLATION 33 Worktop cut out surface mounted B 500 1 ßR 4 B 10 0 10 1 1 ...
Page 40: ...Installation INSTALLATION 40 Front view ...
Page 41: ...Installation INSTALLATION 41 View from above ...
Page 60: ...Installation INSTALLATION 60 Air duct dimensions flush fit worktop depth 600 mm Side view ...
Page 62: ...Installation INSTALLATION 62 Front view ...
Page 63: ...Installation INSTALLATION 63 View from above ...
Page 77: ......
Page 78: ......