Installation
*INSTALLATION*
32
Installing several
SmartLine appliances
The gaps between the individual
SmartLine appliances must be sealed
with a silicone sealant that is heat-
resistant to at least 160 °C. With flush-
fit installation, the gap between the
SmartLine appliance(s) and the worktop
must also be sealed with a silicone
sealant that is heat-resistant to at least
160 °C.
After installation, the SmartLine
appliances must be easily accessible
from below, so that the bottom half of
the casing can be removed for
maintenance. If the SmartLine
appliances are not accessible from
below, the sealant must be removed so
that they can be removed.
Worktop depth
The downdraft extractor can be
installed with the connector for the air
duct on either the right or the left-hand
side.
Minimum worktop depth for
- right connector 600 mm
- left connector 665 mm