www.midtronics.com
2 – Module Balance
xMB-9640
15
2 – Module Balance
Module
Balance
Use this function to charge or discharge a module of a battery pack according to
target voltage, to bring it in balance with the other modules of the pack.
Hazardous voltage.
An improper connection can result in
electric shock
To avoid electrical shock or burn, never alter the xMB-
9640’s original AC cord and plug. Disconnect plug
from outlet when the xMB is idle.
IMPORTANT:
Make sure to properly prepare the battery pack by following all required
guidelines Refer to your documentation for complete information.
Before balancing a battery module, make sure all of the external components connected
to the xMB-9640 are in good working order.
Parameters
Discharge
–
Discharge mode set to constant current –
constant voltage
– Maximum discharge current is 40A up to
48V / 20A up to 96V max
Charge
– Charge mode set to constant current –
constant voltage
– Charge current is 40A up to 48V / 20A up to
96V or module max
Procedure
1.
Confirm that the appropriate safety equipment is in place and press
Confirm
.
2.
At the Main Menu, select Module Balance.