background image

www.midtronics.com

MDX-650P SOH

13

Decision

Interpretation

HIGH OUTPUT

Alternator voltage output exceeds the normal limits.
√  Make sure there are no loose connections and 

the ground connection is normal. If there are no 

connection problems, replace the regulator. Most 

alternators have a built-in regulator that requires 

replacing the alternator. In older vehicles that 

use external voltage regulators, you may need to 

replace only the voltage regulator.

EXCESSIVE 

RIPPLE

Excessive AC ripple detected.
√  One or more diodes in the alternator is not 

functioning or there is stator damage.

6.  Press 

 

6

 to print the test results or   to return to the Options Menu.

Test Messages

For a more decisive result, the tester may prompt you for additional 

information.  The messages in the following table may appear before the tester 

can display a result.

Test Message

Interpretation

BAT. TEMPERATURE

Select ambient temperature above or below 32 ºF (0 ºC)

CHARGE STATE

Select before or after battery has been charged.

SURFACE CHARGE 

DETECTED

Remove the surface charge before it begins testing.  

Testing will resume after charge has been removed.

CHECK 

CONNECTION

One or both clamps are not making proper contact with 

the battery terminals.

ENGINE REV NOT 

DETECTED PRESS

  

  

WHILE REVVING

Tester has not detected an increase in engine rpm

REVERSE 

CONNECTION

Clamps are connected in the wrong polarity:  

positive to negative or negative to positive. 

SYSTEM NOISE 

CHECK LOADS

In-vehicle testing.  Tester has detected computer, ignition 

noise or parasitic drain.  Make sure all vehicle loads are 

off including open doors and ignition switch.

UNSTABLE 

BATTERY

Out-of-vehicle.  Weak battery, should be charged and 

retested.

WIGGLE  

CLAMPS

Clamps are not making good contact with  

battery terminals

Summary of Contents for MDX-650P SOH

Page 1: ...ww midtronics com MDX 650P SOH 1 For 6 12 volt automotive starting batteries and 12 24 volt starting charging systems INSTRUCTION MANUAL Battery Conductance and Electrical System Analyzer MDX 650P SOH...

Page 2: ...Blank page...

Page 3: ...6 Next 6 6 Back Print 6 Menu 6 Options Menu 7 Procedure 7 Preparations Before the Test 8 Connecting the Tester 8 Battery System Test 9 Starter System Test 11 Charging System Test 12 Test Messages 13 E...

Page 4: ...www midtronics com MDX 650P SOH 4...

Page 5: ...lectrical System Analyzer tests 6 12 volt regular flooded AGM flat plate AGM spiral EFB and gel batteries as well as 12 24 volt starting and charging systems for passenger cars and light trucks It dis...

Page 6: ...connected to the battery briefly press and hold the button User Interface 1 p q Arrows Use these keys to choose test parameters and scroll to menu options 2 Next Use this button to make selections 3...

Page 7: ...Reader program under development PERFORM TEST Begin the Battery Test procedure SET ADDRESS Enter the address to display on the top of the printout Limit 8 lines 21 characters per line TIME Select 24...

Page 8: ...n the adapters more than turn If you are testing in the vehicle make sure all accessory loads are off the key is not in the ignition and the doors are closed Connecting the Tester Connect the red clam...

Page 9: ...T where applicable 3 APPLICATION Scroll to and select AUTOMOTIVE MOTORCYCLE MARINE LAWN GARDEN GROUP 31 or COMMERCIAL 4D 8D 4 BATTERYTYPE Scroll to and select REGULAR FLOODED AGM FLAT PLATE EFB AGM SP...

Page 10: ...est A REPLACE BATTERY result may also mean a poor connection between the battery cables and the battery After disconnecting the battery cables retest the battery using the out of vehicle test before r...

Page 11: ...N CRANKING TIME 10 20V 718mS 6 Starter Decision Cranking time in milliseconds Average cranking voltage Decision Interpretation CRANKING NORMAL The starter voltage is normal and the battery is fully ch...

Page 12: ...is showing normal output from the alternator NO OUTPUT No alternator output detected Check all connections to and from the alternator especially the connection to the battery If the connection is loo...

Page 13: ...g table may appear before the tester can display a result Test Message Interpretation BAT TEMPERATURE Select ambient temperature above or below 32 F 0 C CHARGE STATE Select before or after battery has...

Page 14: ...ES SOON Internal AA batteries are low and need to be replaced See Maintenance Troubleshooting section NON 12 VOLT SYSTEM DETECTED System being tested is not 12 volts PRINTER DOOR OPEN CLOSE DOOR AND T...

Page 15: ...le away from the tester 2 Remove the circled screw and firmly pull the cable assembly base out of the tester body 3 Remove the two screws holding the cable assembly base cover 4 Remove the cover 5 Sli...

Page 16: ...5 Store Part Number Phone Office Depot 209 653 271 800 463 3768 Quill 856607 800 789 1331 Staples 531236 800 378 2753 To replace the paper roll 1 Unlock the printer door by gently pressing on the red...

Page 17: ...be properly connected to a vehicle battery having at least 9 volts 9 9 Connect to a vehicle battery with enough voltage to enable printing 9 9 Make sure that the clamps are connected properly red clam...

Page 18: ...OTE Setup information will be retained while you change the internal batteries Use the following procedure to remove and replace the internal AA batteries 1 Turn the tester face down 2 Remove the scre...

Page 19: ...www midtronics com MDX 650P SOH 19...

Page 20: ...thorization number and return the unit to Midtronics freight prepaid Attention RA Midtronics will repair or replace the tester and reship the next scheduled business day following receipt using the sa...

Reviews: