Midtronics B.V. Hoofdveste 6 - 8 Houten NL
www.midtronics.com
19
EXP-1080 JLR
Chapter 9: Troubleshooting
If you have problems with the display or printer try these
troubleshooting suggestions:
Problems with the display
The display does not turn on:
•
Check the connection to the battery.
•
The analyzer’s internal batteries may need to be re-
placed.
The display flickers or is dim:
•
The contrast may need to be adjusted in the Utility
menu.
•
The analyzer’s internal batteries may need to be re-
placed.
The STATUS LED Flashes
When a printer fault occurs, the
STATUS
LED flashes. You
can identify the fault by the number of sequential flashes:
Sequence
Condition
Solution
* * *
No paper
Insert new paper
** ** **
Thermal head too hot
Allow head to cool
*** *** ***
Batteries weak
Recharge printer batteries for
16 hours
Data Will Not Print
•
If the IR transmitter and receiver are not aligned, all the
data may not print. The infrared ports on the top of the
analyzer and on the printer below the
MODE
button
should be pointed directly at each other. The maximum
distance for reliable transmission between the ports is
17 in (45 cm).
To realign, press the
END
button to cancel the print job.
Verify alignment between the analyzer and printer; then
try to print the test results again.
•
Make sure the printer is on. The printer shuts off after 2
minutes of inactivity to conserve the batteries. To turn
the printer on, briefly press the
MODE
button. The
green
STATUS
light should turn on. Make sure you are
using the Midtronics printer. Other printers may not be
compatible.
Chapter 9: Troubleshooting