Midtronics JLR EXP-1080 Instruction Manual Download Page 16

Midtronics B.V.     Hoofdveste 6 - 8     Houten NL

www.midtronics.com

16

EXP-1080 JLR

Chapter 8: Utility Menu

The Utility Menu allows you to easily set up your analyzer:

Config Tester

TIME :

9:07

MODE :

24 HOUR

DATE :

01/10/2013

FORMAT :

/

MM/DD/YYYY

TEMP. UNITS :

°C

WRITE FAIL :

ASK

Time

1.  Use the LEFT/RIGHT ARROW keys to highlight the hour 

or minutes. To rapidly scroll, hold down an ARROW key.

9

: 07

AM

2.  Press the 

SAVE

 softkey to save your setting or BACK to 

return to the ADJUST screen.

Mode

Use the 

LEFT/RIGHT ARROWS

 to select the option of your 

choice.
1.  Select the 24-hour or AM/PM mode
2.  Press the OK softkey to save your setting

Date

Date cannot be changed.

Format

Use the 

UP/DOWN ARROWS

 to select the desired option.

1.  MM/DD/YYY (month/day/year) or DD/MM/YYY (day/

month/year)

2.  Press the OK softkey to save your setting.

Temperature Units

Use the 

LEFT/RIGHT ARROWS

 to select either Celsius or 

Fahrenheit as temperature indication.

Write Fail

After each measurement the test results are stored on the 

data card. In case the data cannot be stored on to the card 

you can select the way this is notified to the operator.
 

ASK (operator is asked if it is ok to continue even when 

results are not stored)

 

FORCE (measurements can only continue when data 

card is entered)

 

IGNORE (measurement is not stored and operator not 

notified)

Display

The LCD OPTIONS utility enables you to adjust the contrast 

of the text on the display and the backlight time.

Contrast Level

The contrast level is 0 (lightest) to 10 (darkest).  To change it:
1.  Press the 

UP

 or 

DOWN ARROW

 to highlight the op-

tion. 

CONTRAST LEVEL

10

BACKLIGHT TIME

60

2.  Press the 

LEFT/RIGHT ARROW 

key to display the op-

tion’s numerical scroll box.

10

(1-10)

3.  Press the 

UP/DOWN ARROW

 keys to select your pref-

erence.

4.  Press the 

SAVE

 softkey to save your setting or the BACK 

softkey to return to the CONTRAST LEVEL screen without 

saving the changes.

Backlight Time

Backlight time is from 0 to 60 seconds. To change it:
1.  Press the 

UP

 or 

DOWN ARROW

 to highlight the op-

tion. 

CONTRAST LEVEL

10

BACKLIGHT TIME

60

2.  Press the 

LEFT/RIGHT ARROW 

key to display the op-

tion’s numerical scroll box.

60

SEC

Chapter 8: Utility Menu

Summary of Contents for JLR EXP-1080

Page 1: ...Vehicle Battery Diagnostic Platform For testing 6 and 12 volt automotive batteries INSTRUCTION MANUAL JLR EXP 1080...

Page 2: ......

Page 3: ...le 10 Setting User Preferences 10 Chapter 3 Test Preparation 10 Additional Test Requirements and Messages 11 System Noise 11 Unstable Battery Detected 11 Surface Charge 11 Deep Scan Test 11 Chapter 4...

Page 4: ...ys wear proper safety glasses or face shield when working with or around batteries Keep hair hands and clothing as well as the analyzer cords and cables away from moving engine parts Remove any jewelr...

Page 5: ...structions and safety and danger notices performing all stipulated inspection and servicing work following all instructions from the battery and vehicle manufacturers Disposal Do not dispose of this d...

Page 6: ...DB 9 connector for future expandability Removing and Inserting the Data Card The analyzer ships with a storage card slot to protect it from dust and debris To remove the data card push briefly on its...

Page 7: ...e SELECT BACK and END POWER Key Press the POWER button to turn the analyzer on and off The analyzer also turns on automatically when you connect its test leads to a battery Title Bar The title bar sho...

Page 8: ...the UP DOWN ARROW keys to move the dot into the button next to the item you want You can also use the alphanumeric keypad to enter the number preceding the option button To confirm your selection pre...

Page 9: ...sults before you retest select a test type in the Print View Menu Icon Description Displays the last test results Displays the last QC test result Info Menu Icon Description TOTALS displays the total...

Page 10: ...are off the key is not in the ignition and the doors are closed If systems in the vehicle are still active it might lead to a SYSTEM NOISE message the tester will automatically continue to test the b...

Page 11: ...wing messages and instructions may appear before the analyzer displays the results of your test System Noise To perform a correct measurement the tester requires the vehicle to be in rest After the ca...

Page 12: ...GE RETEST Fully charge the battery and retest Failure to fully charge the battery before retesting may cause false readings If CHARGE REQUIRED appears again after you fully charge the battery replace...

Page 13: ...ress the NEXT softkey to continue The BACK softkey returns you to the previous screen 4 Select the BATTERY RATING Press the UP and DOWN ARROW keys to select the rating In case of a JIS battery type th...

Page 14: ...te the results in memory View Test VIEW TEST gives you the option of viewing and printing all available test results To return to the Main Menu press the END key To print the results press the PRINT k...

Page 15: ...decision performed since the Tester was first used The other option is to clear all the counters from the tester Transfer The TRANSFER utility lets you transfer test data to a PC using an optional IR...

Page 16: ...stored on the data card In case the data cannot be stored on to the card you can select the way this is notified to the operator ASK operator is asked if it is ok to continue even when results are no...

Page 17: ...and after lines of text or insert spaces between words 5 Press the SAVE softkey to save your setting or the BACK softkey to return to the SHOP INFO screen without sav ing the changes Coupon The COUPON...

Page 18: ...off during the proces 2 Insert the disc in the tester 3 Select one of the options and follow the instructions on the screen 4 When finished the tester will prompt you to remove the card and reboot th...

Page 19: ...new paper Thermal head too hot Allow head to cool Batteries weak Recharge printer batteries for 16 hours Data Will Not Print If the IR transmitter and receiver are not aligned all the data may not pr...

Page 20: ...e battery pack is fully charged It gradually changes to white as the charge level declines The Tester will display a warning message when the batteries need replacing Full Powered by vehicle battery D...

Page 21: ...t static damage water damage overvoltage damage dropping the unit or damage resulting from extraneous causes including owner misuse Midtronics is not liable for any incidental or consequential damages...