8
9
midstreamlighting.com call +44 (0) 207 584 8310
MODUS R 1000 INSTALLATION GUIDANCE
30
9
Stripping the cable
Strip one end of the floodlight connection cable to a
length of circa 30 mm, then expose the conductors for
9mm.
(The cable from the driver to the floodlight is not supplied,
the cable used must be an outdoor rubber cable
H05RN-F or equivalent.)
The device has a type Y attachment. If it becomes
damaged, it should only be replaced by the manufacturer
or by its service staff.
Take a TH405 Connector socket. The connector and its
housing are supplied in 2 pieces.
SCALE 1:2
SEE DETAIL
A
7. Floodlight connection
7a. Floodlight connection with an IP68 connector
Unscrew the cover
Unscrew the 4 x M5 screws. Then remove the plastic cap from the connector plug, push towards the connector side
and remove the cover.
Connecting via cable gland
Remove the 2 countersunk screws to remove the junction box lid. Insert the cable for the floodlight through the cable
gland. Remove the cable sheath for 65 mm to facilitate connection of the wires.
SCALE 1:2
SEE DETAIL
A
Cable gland
Adapting the grommet
Remove the inside part of the grommet, when the cable
diameter is greater than 9 mm. To remove the gasket,
remove cable gland nut first.
Follow these instructions to connect the floodlight via IP68 connector, to connect the floodlight with direct wiring skip
to page 14.