22
VX-4500 & VX-4600
:
For the VX-4500 & VX-4600 radio programming software CE-115 v1.01 or higher must be used.
Read the radio with the option board installed. Select “Common” from the menu and then “Option”. The “Option
Unit” should be read as “FVP-35”.
Under the “Common” heading select “Key Function” to set which key will control the Emergency ANI or Lone
Worker on/off. Set the “P1-P4” or “A” button to “Option Switch 1”.
Download the program to the radio.
VX-4000, VX-5500 & VX-6000
:
For the VX-4000 radio programming software CE-35 v2.0.2.0 or higher or CE-49 v3.3.0.0 or higher must be used.
For the VX-5500/VX-6000 radio programming software CE-49 v3.3.0.0 or higher must be used.
Read the radio with the option board installed. Select “Common” from the menu and then “Option”. Set the
“Option Unit” to “FVP-35 (Hi Level Encr)”. This will also change the “Encryption Type” setting under “Common” >
“Miscellaneous” to “Hi Level”.
Under the “Common” heading select “Key Function” to set which key will control the Emergency ANI or Lone
Worker on/off. Set the PF1-PF5 (long or short) button to “Hi-Level Enc SW”.
In the main screen, in the “ENCR” column, every channel must have the flag checked. NOTE: This does not
provide encryption on a per channel basis.
Download the program to the radio.