2
3B
SPECIFICATIONS
Operating Voltage
4.75-8.2 VDC
Operating Current:
Power Save Mode (COR Operation)
2.5 mA typical
Repeat Operation
17.5 mA typical
Average w/COR Power Save (80-10-10 cycle)
<5 mA
Average w/COR Power Save (90-5-5 cycle)
<4 mA
Operating Temperature
-30 - +60 C
Frequency Response
300-3000 Hz
Input Impedance
>45 k
Ω
Input Level (TX)
0.05-2.5 VPP
Input Level (RX)
0.05-2.5 VPP
Audio Output Impedance
< 1200 Ohm
5B
INSTALLATION OVERVIEW
1. Test the radio for functionality.
2. Program the radio per the Radio Programming Section of this manual.
3. Install the unit into the radio per the Hardware Installation Section of this manual.
4. Program the unit per the Product Programming Section of this manual.
Note: Midian is not responsible for any damage/loss resulting from the use of Midian’s products.