6 SYSTEM

 

ERROR

 

MESSAGES 

 

CHANNEL BUSY 

Reason:

 An attempt was made to transmit or make a 

call on a busy channel with busy lockout enabled. 

Solution:

 Wait until the channel is clear before 

transmitting. 

 

DATABASE EMPTY 

Reason:

 An attempt was made to edit or delete a user 

when the database was empty. 

Solution:

 These functions do not apply when the 

database is empty. 

 

DATABASE FULL

 

Reason:

 An attempt was made to add a user to the 

database and there is no more room. The maximum 
number of user aliases of 137 cannot be exceeded. 

Solution:

 Remove any old user names that are no 

longer in service. If this is not possible, contact Midian 
to learn about our Computer Aided Dispatch (CAD) 
fleet management systems which can handle many 
more users. 

 

DATABASE ERROR

 

Reason:

 One or more entries in the user database has 

been corrupted. This can happen if power is lost at the 
exact time the database is being updated. Any 
corrupted records will be blanked-out and must be re-
entered. 

Solution:

 Cycle power to the unit. This should clear the 

error. If the error message continues to come up, 
contact Midian technical support. 

 

DUPLICATE ID

 

Reason:

 An attempt was made to add a user ID to the 

database which is already in the database. Each user 
ID in the database must be unique. 

Solution:

 Choose a unique user ID for each user. If it is 

necessary to edit the user record, use the edit menu. 

 

EE CHKSUM ERR

 

Reason:

 The configuration settings stored in EEPROM 

have been corrupted. This can happen if power is lost 
at the exact time a parameter is being updated. All 
configuration settings will be set back to defaults. The 
user database should not be affected. 

Solution:

 Cycle power to the unit. This should clear the 

error. If the error message continues to come up, 

contact Midian technical support. 

 

EE WRITE FAIL

 

Reason:

 The EEPROM chip or connections to it have 

failed. 

Solution:

 Contact Midian for instructions on getting the 

unit repaired. 

 

FIELD IS BLANK

 

Reason:

 An attempt was made to place a call, but the 

user ID or name was blank. An attempt was made to 
spy or kill and the respective field in the database is 
blank. 

Solution:

 When placing a call, be sure an ID number or 

user name is displayed before pressing <SEND>. The 
spy and kill functions require there be an entry in the 
respective field of the user database. 

 

MODEM TIMEOUT

 

Reason:

 The DDU expects a call to be completed 

within 4.5 seconds and this time has been exceeded. 
This can happen if the total of the key-up delay and 
tone widths exceed 4.5 seconds. This can also happen 
when used in a trunking system and a channel cannot 
be acquired. It is also possible that there could be a 
hardware failure. 

Solution:

 If total time of the key-up delay and signaling 

tones exceeds 4.5 seconds, simply press <SEND> to 
clear the message from the display. The call will still be 
sent. If the timeout is caused by excessive channel 
acquisition time in a trunking system, press <SEND> to 
clear the error and try placing the call again. In the 
event of a hardware failure, contact Midian technical 
support to determine if that is the cause. 

 

NOT FOUND

 

Reason:

 There is no entry in the user database that 

matches the data entered. 

Solution:

 When selecting a user to call, the name or 

the ID can be entered in whole or in part. When 
entering a partial name or ID, press the right 
<SCROLL> button to search the database for the first 
partial match. Press <SEND> only if the whole ID or 
name has been entered. There may be no entry in the 
database that matches in whole or in part. In that case, 
the user must be added to the database. 

 
 

 

 

Summary of Contents for DDU-100

Page 1: ...Controller with 5 Tone Encode ANI Decode INSTRUCTION MANUAL Model Features 10 entry ANI recall memory 137 entry alias database Auto mute leading ANI Alternate function as a repeater access controller Programmable encode decode format Supports DTMF and several 5 tone formats Easy to read backlit LCD display Serial printer logging w optional cable MANUAL REVISION 2013 07 22 COVERS PRODUCT SOFTWARE V...

Page 2: ...mA Inputs Input Level RX 100 3000 mV p p Input Impedance RX 10k Outputs Output Level TX unloaded 150 2500 mV p p Output Impedance TX 27k with JU4 cut Speaker Audio Output 1 W into 8 Mechanical Dimensions 2 H x 6 W x 8 L Operating Temp 0 to 50 C Encode Decode Formats DTMF CCIR EEA EIA ZVEI DZVEI DDZVEI NATEL and MODAT Other Max ANI Length 8 digits ANI Recall Stack Size 10 Alias Database Size 137 ...

Page 3: ...INTERFACE 4 3 2 JUMPER SETTINGS 5 3 3 ADJUSTMENTS 5 3 4 CONFIGURATION SETTINGS 5 4 BASIC OPERATION 5 4 1 DISPLAY MODE 5 4 2 MENU MODE 6 4 3 USER DATABASE 7 4 4 STATUS DISPLAY FEATURE 8 5 MENU SYSTEM 8 5 1 CALL COMMAND 8 5 2 LOCK OR UNLOCK COMMAND 8 5 3 ACTIONS MENU 8 5 4 USERS MENU 8 5 5 SETUP MENU 9 6 SYSTEM ERROR MESSAGES 14 7 MENU SYSTEM MAP 15 ...

Page 4: ...The output impedance of the DDU can be adjusted if necessary by replacing leaded resistor R81 with an appropriate value PTT OUTPUT P1 3 Yellow This open collector output provides a ground to key up the radio when transmitting If connecting to a relay in the radio make sure the coil is bypassed with a diode to eliminate counter EMF This output may also be assigned to be the repeater access control ...

Page 5: ...ntrol settings are at desired levels 3 4 CONFIGURATION SETTINGS Once adjustments have been made it will be necessary to configure the DDU to meet the system requirements This is done via Menu Mode The most crucial settings include Decode Format and Encode Format if using encode feature Refer to ENC DEC SETUP menu item Pay close attention to Encode Time 1 2 and Decode Time as well It is also import...

Page 6: ... the CALL command The scroll right symbol on the right side of the display indicates that additional items are available Press the right SCROLL button to view the next available item The scroll left symbol will then appear indicating that the left SCROLL button may be used to go back to the previous item To select the displayed item press the SEND button the SEND button acts like an ENTER key when...

Page 7: ...y from the CALL menu Also these special sequences should not be used unless you are using DTMF as the encode or decode format 4 2 7 Locking and Unlocking the Menus The menu system incorporates a lock feature to prevent unauthorized personnel from changing the DDU configuration The lock feature also serves to simplify day to day operation of the unit When the LOCK command is selected all of the men...

Page 8: ...the option to enter the numeric ID of the unit you wish to call If the user database is set up you may use the right SCROLL buttons to go into Select Mode and find the name of the user to be called using the left and right SCROLL keys Alternatively you can enter the User ID or User name in part or in whole When entering the complete name or ID simply press SEND to place the call When entering a pa...

Page 9: ... option This causes a siren sound to be heard when an emergency ANI is received This requires turning on the Emerg Status option in the STATUS SETUP menu OFF Do not sound siren on emergency ANI ON Sound siren on emergency ANI 5 5 1 4 Internal Speaker setting Normally the internal speaker is on This is required in order for key beeps error beeps confirmation beeps and other system sounds to be hear...

Page 10: ...5 5 RADIO SETUP menu 5 5 5 1 Keyup Delay setting This sets the Key Up Delay also known as Front Porch Time This is the amount of time the DDU will wait after asserting PTT before sending tones over the air This time allows for delays introduced by repeaters and decoding of squelch control signals such as CTCSS Range 0005 to 4000 milliseconds Default 0400 milliseconds 5 5 5 2 COR Polarity setting D...

Page 11: ...one widths Non standard tone widths are permitted allowing for faster encode When using DTMF format This is the tone ON time for DTMF format Range 0005 to 1000 milliseconds Default 0050 milliseconds 5 5 6 3 Encode Time 2 setting When using 5 tone formats non DTMF This is the duration of each of the remaining tones or digits of the encode sequence Normally this should be the same as Encode Time 1 W...

Page 12: ...lid ANI will also be required to keep the repeater open COR Reset hang timer if COR goes active before the hang time expires COR ANI Require both COR and an ANI or valid User ID to reset the hang timer before expiration 5 5 7 5 Repeater Out setting This setting specifies which output is used to put the repeater into transmit mode when Repeat Control is enabled PTT PTT output used to key repeater i...

Page 13: ... Msg setting See Status 0 Msg setting above Range 0 10 characters Default blank 5 5 8 11 Status 8 Msg setting See Status 0 Msg setting above Range 0 10 characters Default blank 5 5 8 12 Status 9 Msg setting See Status 0 Msg setting above Note that this status message is associated with emergency status Range 0 10 characters Default blank 5 5 9 UTILITIES menu 5 5 9 1 Reset Defaults This will reset ...

Page 14: ...tion Cycle power to the unit This should clear the error If the error message continues to come up contact Midian technical support EE WRITE FAIL Reason The EEPROM chip or connections to it have failed Solution Contact Midian for instructions on getting the unit repaired FIELD IS BLANK Reason An attempt was made to place a call but the user ID or name was blank An attempt was made to spy or kill a...

Page 15: ...MIDIAN ELECTRONICS INCORPORATED PAGE 15 DDU 100 200 Manual 7 MENU SYSTEM MAP ...

Page 16: ... COC63 PIC6401 PIC6402 COC64 PIC6501 PIC6502 COC65 PIC6601 PIC6602 COC66 PIC6701 PIC6702 COC67 PIC6801 PIC6802 COC68 PIC6901 PIC6902 COC69 PIC7001 PIC7002 COC70 PIC7101 PIC7102 COC71 PIC7201 PIC7202 COC72 PIC7301 PIC7302 COC73 PIC73A01 PIC73A02 COC73A PIC73B01 PIC73B02 COC73B PIC7401 PIC7402 COC74 PIC7501 PIC7502 COC75 PIC7601 PIC7602 COC76 PIC7701 PIC7702 COC77 PIC7801 PIC7802 COC78 PIC7901 PIC79...

Page 17: ...5801 COR58 PAR5902 PAR5901 COR59 PAR6002 PAR6001 COR60 PAR6102 PAR6101 COR61 PAR6202 PAR6201 COR62 PAR6302 PAR6301 COR63 PAR6402 PAR6401 COR64 PAR6502 PAR6501 COR65 PAR6602 PAR6601 COR66 PAR6702 PAR6701 COR67 PAR6802 PAR6801 COR68 PAR6902 PAR6901 COR69 PAR7002 PAR7001 COR70 PAR7102 PAR7101 COR71 PAR7202 PAR7201 COR72 PAR7302 PAR7301 COR73 PAR7402 PAR7401 COR74 PAR7502 PAR7501 COR75 PAR7602 PAR7601...

Page 18: ...C O t b 0 s c h 2 P A V O 2 0 1 P A V O 2 0 2 PAVO2013 PAVO2012 PAVO2011 PAVO2010 PAVO209 PAVO208 PAVO207 PAVO206 PAVO205 PAVO204 PAVO203 C O V O 2 ...

Page 19: ... This page intentionally left blank ...

Page 20: ... COLED1 1 PILED102 PILED103 COLED1 2 PILED201 PILED202 COLED2 1 PILED202 PILED203 COLED2 2 PIP601 COP6 1 PIP602 COP6 2 PIP603 COP6 3 PIP604 COP6 4 PIP605 COP6 5 PIP606 COP6 6 PIP607 COP6 7 PIP608 COP6 8 PIP609 COP6 9 PIP6010 COP6 10 PIP6011 COP6 11 PIP6012 COP6 12 PIP6013 COP6 13 PIQ80B PIQ80C PIQ80E COQ8 PIQ90B PIQ90C PIQ90E COQ9 PIQ100B PIQ100C PIQ100E COQ10 PIR3A01 PIR3A02 COR3A PIR3B01 PIR3B02...

Page 21: ...34B01 PAR34B02 COR34B PAR54A01 PAR54A02 COR54A PAR54B02 PAR54B01 COR54B PAR77A01 PAR77A02 COR77A PAR77B02 PAR77B01 COR77B PAR9802 PAR9801 COR98 PAR9901 PAR9902 COR99 PAR10002 PAR10001 COR100 PAR10101 PAR10102 COR101 COtb0sch1 PAVO10C PAVO10B PAVO10E PAVO101 PAVO102 PAVO103 PAVO104 PAVO105 PAVO106 PAVO107 PAVO108 PAVO109 PAVO1010 PAVO1011 PAVO1012 PAVO1013 PAVO100 COVO1 COVO4 ...

Page 22: ... A S W 7 0 0 P A S W 7 0 2 P A S W 7 0 1 C O S W 7 P A S W 8 0 0 P A S W 8 0 2 P A S W 8 0 1 C O S W 8 P A S W 9 0 0 P A S W 9 0 2 P A S W 9 0 1 C O S W 9 P A S W 1 0 0 0 P A S W 1 0 0 2 P A S W 1 0 0 1 C O S W 1 0 P A S W 1 1 0 0 P A S W 1 1 0 2 P A S W 1 1 0 1 C O S W 1 1 P A S W 1 2 0 0 P A S W 1 2 0 2 P A S W 1 2 0 1 C O S W 1 2 P A S W 1 4 0 0 P A S W 1 4 0 2 P A S W 1 4 0 1 C O S W 1 4 P A S...

Reviews: