How To Use The Advanced Functions

When the air conditioner operates under 
heating mode with the set temperature of 

O

O

16 C(60 F), pressing        button twice in

O

O

one second will activate 8 C(46 F) heating. 
The indoor unit display shows    FP   . 

,,

, ,

FP  function

The 

Boost

 function makes the unit work 

extra hard to reach your present temperature 

in the shortest amount of time possible.  
   When you select 

Boost

 feature in 

COOL 

   mode, the unit will blow cool air with 
   strongest wind setting to jump-start the 
   cooling process.
    
    
       

  

   When you select Turbo feature in 

HEAT

 

   mode, the unit will blow heat air with 
   strongest wind setting to jump-start the 
   heating process.  

   Press the Swing button to start or stop the
   horizontal louver auto swing feature. 
   If continue to press the Swing button, five 
   different airflow directions can be set. The 
   louver can be move at a certain range each 
   time you press the button. 
   Hold down the Swing button for 2 seconds
   will start or stop the vertical louver auto swing
   feature. 
   
    

Boost function(       )

Swing function

NOTE:

Silence function

Hold down Fan speed button(      ) for 2 seconds
to activate/cancel 

Silent

 mode. Due to low 

frequency operation of compressor, it may result 
in insufficient cooling and heating capacity
(applicable to the air conditioner with Silent 
feature only)

ECO/GEAR function(        )

ECO operation:

GEAR operation:

How To Use The Advanced Functions

NOTE:

 This function is only available under 

COOL mode.
  Press ECO/GEAR button to enter the energy
  efficient mode in a sequence of following:
  

ECO     GEAR(75%)      GEAR(50%)      

  Previous setting mode       ECO      ......
  

Under cooling mode, press this button, the
remote controller will adjust the temperature

O

automatically to 24 C, fan speed of Auto to
save energy(but only if the set temperature

O

is less than 24 C). If the set temperature is 

O

above 24 C , press the ECO button, the fan 
speed will change to Auto, the set temperature 
will remain unchanged.

NOTE:

Pressing the ON/OFF button, modifying the 
mode or adjusting the set temperature  to less 

O

than 24 C will stop ECO operation.
Under ECO operation, the set temperature

O

should be 24 C or higher. it may result in 
insufficient cooling. If you feel uncomfortable,
 just press the ECO button again to stop it.

Press this button to enter the energy efficient
mode in a sequence of following:    
 75% 

(up to 75% electrical energy consumption)

 50%

 (up to 50% electrical energy consumption)

  Previous setting mode
     

This function is only available under COOL
mode.
Under GEAR operation, the display on the 
remote controller will alternate between 
electrical energy consumption and set
temperature. 

 When the unit is off, press and hold 
 

Mode

 and 

Swing

 buttons together for 

 one second, the louver will open for
 a certain angle, which makes it very
 convenient for cleaning.
 Press and hold 

Mode 

and 

Swing

 buttons together for one second to 
reset the louver.

 

Active Clean Function(       )

This function is used to clean the air 
conditioner evaporator to prevent frosting.
When this function is turned on, the indoor
unit display window appears   CL  , after 20 
to 45 minutes, the unit will turn off automatically 
and cancel Active Clean function. 

, ,

,,

Fan

Boost

Fan

Boost

Summary of Contents for RG10A(B2S)/BGEF

Page 1: ...sing our air conditioner Please read this owner s manual carefully before using your air conditioner Make sure to save this manual for future reference The design and specifications are subject to cha...

Page 2: ...ful interference and 2 this device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits fo...

Page 3: ...other materials and direct sunlight can interfere with the infrared signal receiver Remove batteries if the remote control will not be used more than 2 months INSERTING AND REPLACING BATTERIES INSTAL...

Page 4: ...ration The operating temperature range for units is O O 16 30 C 60 86 F You can increase or O O decrease the set temperature in 1 C 1 F increments COOL operation Low battery detection display If flash...

Page 5: ...s LCD screen will not display temperature DRY operation dehumidifying FAN operation 1 Press the MODE button to select HEAT mode 2 Set your desired temperature using the Temp or Temp button 3 Press the...

Page 6: ...er which the unit will automatically turn off TIMER ON function The TIMER ON function allows you to set a period of time after which the unit will automatically turn on Your air conditioning unit has...

Page 7: ...rrent time 1PM 2PM 3PM 4PM 5PM 6PM 7PM 8PM 9PM Timer starts Unit turns Unit turns ON OFF 6 hours later 8 hours later Press the SET button to scroll through operation functions as follows Fresh Sleep F...

Page 8: ...nergy efficient mode in a sequence of following ECO GEAR 75 GEAR 50 Previous setting mode ECO Under cooling mode press this button the remote controller will adjust the temperature O automatically to...

Page 9: ...1 10 8 P2 RG10A B2S BGEF...

Reviews: