37
10.3 Key parts checking.
10.3.1. Compressor checking (Model: DA108X1C-20FZ3).
Measure the resistance value of each winding by using the multi-meter.
10.3.2 Outdoor Fan Motor (Model: YDK24-6G).
Measure the resistance value of each winding by using the multi-meter.
10.3.3 Indoor Fan Motor (Model: RPG20D).
Measure the resistance value of each winding by using the multi-meter.
10.3.4 Step Motor (Model: MP2835T).
Measure the resistance value of each winding by using the multi-meter.
Position
Resistance Value
Blue - Red
Blue - Black
Red - Blue
0.71
Ω
(20
℃
)
Position
Resistance Value
Black - Red
435
Ω
(20
℃
)
Blue - Red
213
Ω
(20
℃
)
Yellow - Blue
138
Ω
(20
℃
)
Position
Resistance Value
Black - Red
415
Ω
±8% (20
℃
)
White - Black
290
Ω
±8% (20
℃
)
Position
Resistance Value
Blue - Red
Pink - Orange
Pink - Yellow
Yellow - Red
200
Ω
±7% (25
℃
)
Summary of Contents for MSV1-09HRDN1-QC2
Page 9: ...6 3 Dimension 3 1 Indoor Unit MSV1 09HRDN1 QC2 A 795 165 270 MSV1 12HRDN1 QC2 A 285 845 165...
Page 10: ...7 3 2 Outdoor Unit MOC 09HDN1 QC2 MOC 12HDN1 QC2...
Page 12: ...9 5 Refrigerant cycle diagram...
Page 13: ...10 6 Wiring diagram 6 1 Indoor Unit MSV1 09HRDN1 QC2 A MSV1 12HRDN1 QC2 A...
Page 14: ...11 6 2 Outdoor Unit MOC 09HDN1 QC2 MOC 12HDN1 QC2...
Page 36: ...33 LED1 LED4 LED5 LED6...