47
9. Troubleshooting
9.1 Indoor unit error display
For MS9A-09HRN1-QB8,
MS9A-09HRN1-QC2(2T0032300908),
MS9A-11HRN1-QB8,
MS9A-16HRN1-QB8(A):
Display
LED STATUS
E1
EEPROM error
E2
Zero crossing signal detection error
E3
Indoor fan speed has been out of control
E4
Over current protection of the compressor occurs 4 times
E5
Open circuit or short circuit of room temperature sensor
E6
Evaporator temperature sensor open circuit or short circuit
For 21k,24k models:
Display
LED STATUS
E1
EEPROM error
E4
Over current protection of the compressor occurs 4 times
E5
Indoor room temperature sensor T1 open circuit or short circuit
E6
Evaporator coil temperature sensor T2 open circuit or short circuit
E7
Condenser coil temperature sensor T3 open circuit or short circuit
E9
Indoor / outdoor units communication error
For other models
Operation lamp
Timer lamp
Failure
☆
X
Indoor fan speed has been out of control
☆
O
The T1 or T2 sensor is open circuit or short circuit
X
☆
Over current protection occurs 4 times(for
MS9A-12HRN1-QC2 with BOM code 220032402100,it
doesn’t have this kind of protection)
O
☆
EEPROM error
☆
☆
Zero crossing signal detection error
O
(
light
)
X
(
off
)
☆
(
flash
)