MCAC-VTSM-2016-10
R410A All DC Inverter Mini VRF
Specifications&Performance 51
MDV-V180W/DRN1
Heating
TC: Total Capacity (kW); PI: Power Input (kW) (Comp Outdoor fan motor)
Combination
(%)
(Capacity
index)
Outdoor Air
temperature
(°C DB)
Indoor temperature(°C WB)
16
18
20
21
22
24
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
°C DB
°C WB
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
70%
-13.7
-15
13.12
5.79
13.06
5.92
13.06
6.04
12.82
5.95
12.4
5.71
11.56
5.23
-11.8
-13
13.66
5.89
13.66
6.01
13.3
5.86
12.82
5.64
12.4
5.41
11.56
4.96
-9.8
-11
14.32
5.99
14.14
5.98
13.3
5.54
12.82
5.32
12.4
5.11
11.56
4.69
-9.5
-10
14.68
6.04
14.14
5.8
13.3
5.38
12.82
5.17
12.4
4.97
11.56
4.56
-8.5
-9.1
14.99
6.07
14.14
5.65
13.3
5.23
12.82
5.03
12.4
4.84
11.56
4.45
-7
-7.6
14.99
5.8
14.14
5.4
13.3
5.01
12.82
4.82
12.4
4.63
11.56
4.26
-5
-5.6
14.99
5.45
14.14
5.08
13.3
4.71
12.82
4.53
12.4
5.35
11.56
4.02
-3
-3.7
14.99
5.13
14.14
4.79
13.3
4.45
12.82
4.28
12.4
4.12
11.56
3.8
0
-0.7
14.99
4.67
14.14
4.36
13.3
4.06
12.82
3.91
12.4
3.77
11.56
3.48
3
2.2
14.99
4.27
14.14
3.99
13.3
3.72
12.82
3.58
12.4
3.45
11.56
3.19
5
4.1
14.99
4.03
14.14
3.77
13.3
3.52
12.82
3.39
12.4
3.27
11.56
3.03
7
6
14.99
3.8
14.14
3.56
13.3
3.32
12.82
3.21
12.4
3.1
11.56
2.87
9
7.9
14.99
3.6
14.14
3.37
13.3
3.15
12.82
3.04
12.4
2.93
11.56
2.72
11
9.8
14.99
3.4
14.14
3.19
13.3
2.99
12.82
2.88
12.4
2.79
11.56
2.58
13
11.8
14.99
3.21
14.14
3.02
13.3
2.82
12.82
2.73
12.4
2.64
11.56
2.45
15
13.7
14.99
3.05
14.14
2.86
13.3
2.68
12.82
2.6
12.4
2.51
11.56
2.34
60%
-13.7
-15
12.85
5.95
12.12
5.53
11.4
5.13
11.04
4.93
10.68
4.74
9.95
4.36
-11.8
-13
12.85
5.63
12.12
5.24
11.4
4.86
11.04
4.68
10.68
4.5
9.95
4.16
-9.8
-11
12.85
5.32
12.12
4.95
11.4
4.6
11.04
4.43
10.68
4.26
9.95
3.93
-9.5
-10
12.85
5.17
12.12
4.82
11.4
4.47
11.04
4.31
10.68
4.14
9.95
3.82
-8.5
-9.1
12.85
5.03
12.12
4.69
11.4
4.36
11.04
4.2
10.68
4.04
9.95
3.73
-7
-7.6
12.85
4.81
12.12
4.49
11.4
4.18
11.04
4.03
10.68
3.87
9.95
3.58
-5
-5.6
12.85
4.53
12.12
4.23
11.4
3.94
11.04
3.8
10.68
3.66
9.95
3.38
-3
-3.7
12.85
4.28
12.12
4
11.4
3.73
11.04
3.6
10.68
3.46
9.95
3.2
0
-0.7
12.85
3.91
12.12
3.66
11.4
3.42
11.04
3.3
10.68
3.18
9.95
2.94
3
2.2
12.85
3.58
12.12
3.36
11.4
3.14
11.04
3.03
10.68
2.93
9.95
2.71
5
4.1
12.85
3.39
12.12
3.18
11.4
2.97
11.04
2.88
10.68
2.77
9.95
2.58
7
6
12.85
3.21
12.12
3.01
11.4
2.82
11.04
2.73
10.68
2.64
9.95
2.45
9
7.9
12.85
3.04
12.12
2.86
11.4
2.68
11.04
2.59
10.68
2.5
9.95
2.33
11
9.8
12.85
2.88
12.12
2.71
11.4
2.55
11.04
2.46
10.68
2.38
9.95
2.22
13
11.8
12.85
2.73
12.12
2.57
11.4
2.42
11.04
2.34
10.68
2.26
9.95
2.11
15
13.7
12.85
2.6
12.12
2.44
11.4
2.3
11.04
2.23
10.68
2.16
9.95
2.01
50%
-13.7
-15
10.7
4.77
10.1
4.45
9.5
4.14
9.14
3.99
8.84
3.84
8.24
3.55
-11.8
-13
10.7
4.53
10.1
4.23
9.5
3.93
9.14
3.79
8.84
3.65
8.24
3.38
-9.8
-11
10.7
4.29
10.1
4.01
9.5
3.73
9.14
3.6
8.84
3.47
8.24
3.21
-9.5
-10
10.7
4.17
10.1
3.9
9.5
3.64
9.14
3.51
8.84
3.38
8.24
3.12
-8.5
-9.1
10.7
4.06
10.1
3.81
9.5
3.55
9.14
3.42
8.84
3.3
8.24
3.05
-7
-7.6
10.7
3.9
10.1
3.65
9.5
3.4
9.14
3.29
8.84
3.17
8.24
2.93
-5
-5.6
10.7
3.68
10.1
3.45
9.5
3.22
9.14
3.11
8.84
3
8.24
2.78
-3
-3.7
10.7
3.48
10.1
3.27
9.5
3.05
9.14
2.95
8.84
2.84
8.24
2.64
0
-0.7
10.7
3.19
10.1
3
9.5
2.81
9.14
2.71
8.84
2.62
8.24
2.44
3
2.2
10.7
2.94
10.1
2.77
9.5
2.59
9.14
2.51
8.84
2.42
8.24
2.26
5
4.1
10.7
2.79
10.1
2.62
9.5
2.46
9.14
2.38
8.84
2.31
8.24
2.15
7
6
10.7
2.65
10.1
2.49
9.5
2.34
9.14
2.27
8.84
2.19
8.24
2.05
9
7.9
10.7
2.51
10.1
2.37
9.5
2.23
9.14
2.16
8.84
2.09
8.24
1.95
11
9.8
10.7
2.39
10.1
2.25
9.5
2.12
9.14
2.06
8.84
1.99
8.24
1.86
13
11.8
10.7
2.27
10.1
2.14
9.5
2.02
9.14
1.96
8.84
1.9
8.24
1.78
15
13.7
10.7
2.16
10.1
2.05
9.5
1.93
9.14
1.87
8.84
1.81
8.24
1.7
Note:
1. is tested under our standard condition.
2. In heating mode, avoid running the unit when the outdoor air temperature is below -15 degrees.
3. The above table shows the average value of conditions may operate.
4. It is recommended to connect less than 130%.