MCAC-VTSM-2016-10
R410A All DC Inverter Mini VRF
Specifications&Performance 43
MDV-V160W/DRN1
Heating
TC: Total Capacity (kW); PI: Power Input (kW) (Comp Outdoor fan motor)
Combination
(%)
(Capacity
index)
Outdoor Air
temperature
(°C DB)
Indoor temperature(°C WB)
16
18
20
21
22
24
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
°C DB
°C WB
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
70%
-13.7
-15
11.74
5.53
11.68
5.64
11.68
5.76
11.47
5.67
11.09
5.44
10.34
4.99
-11.8
-13
12.22
5.62
12.22
5.73
11.9
5.59
11.47
5.38
11.09
5.16
10.34
4.73
-9.8
-11
12.82
5.71
12.65
5.71
11.9
5.28
11.47
5.08
11.09
4.88
10.34
4.48
-9.5
-10
13.14
5.76
12.65
5.54
11.9
5.13
11.47
4.93
11.09
4.74
10.34
4.35
-8.5
-9.1
13.41
5.79
12.65
5.39
11.9
4.99
11.47
4.8
11.09
4.61
10.34
4.24
-7
-7.6
13.41
5.53
12.65
5.15
11.9
4.78
11.47
4.6
11.09
4.42
10.34
4.06
-5
-5.6
13.41
5.2
12.65
4.84
11.9
4.5
11.47
4.32
11.09
5.11
10.34
3.83
-3
-3.7
13.41
4.89
12.65
4.57
11.9
4.24
11.47
4.08
11.09
3.93
10.34
3.62
0
-0.7
13.41
4.45
12.65
4.16
11.9
3.87
11.47
3.73
11.09
3.59
10.34
3.32
3
2.2
13.41
4.07
12.65
3.81
11.9
3.55
11.47
3.42
11.09
3.3
10.34
3.05
5
4.1
13.41
3.84
12.65
3.59
11.9
3.36
11.47
3.23
11.09
3.12
10.34
2.89
7
6
13.41
3.63
12.65
3.4
11.9
3.17
11.47
3.06
11.09
2.95
10.34
2.74
9
7.9
13.41
3.43
12.65
3.22
11.9
3
11.47
2.9
11.09
2.8
10.34
2.6
11
9.8
13.41
3.25
12.65
3.04
11.9
2.85
11.47
2.75
11.09
2.66
10.34
2.47
13
11.8
13.41
3.07
12.65
2.88
11.9
2.69
11.47
2.61
11.09
2.52
10.34
2.34
15
13.7
13.41
2.91
12.65
2.73
11.9
2.56
11.47
2.48
11.09
2.39
10.34
2.23
60%
-13.7
-15
11.5
5.67
10.85
5.28
10.2
4.89
9.88
4.71
9.55
4.52
8.9
4.16
-11.8
-13
11.5
5.37
10.85
5
10.2
4.64
9.88
4.47
9.55
4.29
8.9
3.97
-9.8
-11
11.5
5.07
10.85
4.73
10.2
4.39
9.88
4.22
9.55
4.06
8.9
3.75
-9.5
-10
11.5
4.93
10.85
4.6
10.2
4.27
9.88
4.11
9.55
3.95
8.9
3.64
-8.5
-9.1
11.5
4.8
10.85
4.48
10.2
4.16
9.88
4.01
9.55
3.85
8.9
3.56
-7
-7.6
11.5
4.59
10.85
4.29
10.2
3.98
9.88
3.84
9.55
3.69
8.9
3.41
-5
-5.6
11.5
4.32
10.85
4.04
10.2
3.76
9.88
3.62
9.55
3.49
8.9
3.23
-3
-3.7
11.5
4.08
10.85
3.82
10.2
3.56
9.88
3.43
9.55
3.3
8.9
3.05
0
-0.7
11.5
3.73
10.85
3.49
10.2
3.26
9.88
3.15
9.55
3.03
8.9
2.81
3
2.2
11.5
3.42
10.85
3.21
10.2
3
9.88
2.89
9.55
2.79
8.9
2.59
5
4.1
11.5
3.23
10.85
3.04
10.2
2.84
9.88
2.74
9.55
2.65
8.9
2.46
7
6
11.5
3.06
10.85
2.87
10.2
2.69
9.88
2.6
9.55
2.51
8.9
2.34
9
7.9
11.5
2.9
10.85
2.73
10.2
2.55
9.88
2.47
9.55
2.38
8.9
2.22
11
9.8
11.5
2.75
10.85
2.59
10.2
2.43
9.88
2.35
9.55
2.27
8.9
2.12
13
11.8
11.5
2.6
10.85
2.45
10.2
2.3
9.88
2.23
9.55
2.16
8.9
2.01
15
13.7
11.5
2.48
10.85
2.33
10.2
2.19
9.88
2.12
9.55
2.06
8.9
1.92
50%
-13.7
-15
9.58
4.55
9.04
4.24
8.5
3.95
8.18
3.8
7.91
3.66
7.37
3.38
-11.8
-13
9.58
4.32
9.04
4.03
8.5
3.75
8.18
3.62
7.91
3.48
7.37
3.22
-9.8
-11
9.58
4.09
9.04
3.82
8.5
3.56
8.18
3.43
7.91
3.31
7.37
3.06
-9.5
-10
9.58
3.98
9.04
3.72
8.5
3.47
8.18
3.34
7.91
3.22
7.37
2.98
-8.5
-9.1
9.58
3.88
9.04
3.63
8.5
3.38
8.18
3.26
7.91
3.15
7.37
2.91
-7
-7.6
9.58
3.72
9.04
3.48
8.5
3.25
8.18
3.13
7.91
3.02
7.37
2.8
-5
-5.6
9.58
3.51
9.04
3.29
8.5
3.07
8.18
2.97
7.91
2.86
7.37
2.65
-3
-3.7
9.58
3.32
9.04
3.12
8.5
2.91
8.18
2.81
7.91
2.71
7.37
2.52
0
-0.7
9.58
3.05
9.04
2.86
8.5
2.68
8.18
2.59
7.91
2.5
7.37
2.33
3
2.2
9.58
2.81
9.04
2.64
8.5
2.47
8.18
2.39
7.91
2.31
7.37
2.16
5
4.1
9.58
2.66
9.04
2.5
8.5
2.35
8.18
2.27
7.91
2.2
7.37
2.05
7
6
9.58
2.53
9.04
2.38
8.5
2.24
8.18
2.16
7.91
2.09
7.37
1.96
9
7.9
9.58
2.4
9.04
2.26
8.5
2.12
8.18
2.06
7.91
1.99
7.37
1.86
11
9.8
9.58
2.28
9.04
2.15
8.5
2.03
8.18
1.96
7.91
1.9
7.37
1.78
13
11.8
9.58
2.17
9.04
2.04
8.5
1.93
8.18
1.87
7.91
1.81
7.37
1.7
15
13.7
9.58
2.06
9.04
1.95
8.5
1.84
8.18
1.78
7.91
1.73
7.37
1.62
Note:
1. is tested under our standard condition.
2. In heating mode, avoid running the unit when the outdoor air temperature is below -15 degrees.
3. The above table shows the average value of conditions may operate.
4. It is recommended to connect less than 130%.