background image

Summary of Contents for MDDM20

Page 1: ...DEHUMIDIFIER Owner s Manual Installation Manual IMPORTANT NOTE Read this manual carefully before installing or operating your new machine Make sure to save this manual for future reference MDDM20...

Page 2: ...r features 13 Clean the grille and case 17 Clean the bucket 17 Troubleshooting Tips 18 Clean the air filter 17 When not using the unit for long time periods 18 Caster installation and disassembly inst...

Page 3: ...or combustibles such as gasoline benzene thinner etc Do not drink or use the water drained from the unit Do not take the water bucket out during operation Do not use the unit in small spaces Do not pu...

Page 4: ...n damaged contact a technician or customer service for assistance In a thunderstorm the power must be cut off to avoid damage to the machine due to lightning Do not run cord under carpeting Do not cov...

Page 5: ...of such waste separately for special treatment is necessary It is prohibited to dispose of this appliance in domestic household waste For disposal there are several possibilities When using this dehu...

Page 6: ...manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants The appl...

Page 7: ...able material 4 Checking for presence of refrigerant The area shall be checked with an appropriate refrigerant detector prior to and during work to ensure the technician is aware of potentially flamma...

Page 8: ...supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers etc If it is absolutely necessary to have an electrical supply to equipment during servicing t...

Page 9: ...ions on the pipe work are to take place Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available 10 Detection of flammable refrigerants The fo...

Page 10: ...order has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release Consult manufacturer if in doubt The recovered re...

Page 11: ...ehumidifier up pull out the power code and rotate 90 clockwise 3 Place the dehumidifier into the water bucket gently according to the ALIGN label until it clicks in place Do never install it rudely NO...

Page 12: ...help prevent moisture damage The dehumidifier must be operated in an enclosed area to be most effective Close all doors windows and other outside openings to the room A dehumidifier operating in a bas...

Page 13: ...less Mode Wireless light Fresh light Filter clean light Auto deforst light Pump light In Setting dehumidifying mode on some models the set indicator light illuminates On some models the unit without s...

Page 14: ...ted time will register in 5 seconds and the system will automatically revert back to display the previous humidity setting Turning the unit ON or OFF at any time or adjusting the timer setting to 0 0...

Page 15: ...esumes Smart dehumidifying mode On some models Continuous dehumidifying mode At continuous dehumidifying mode the unit dehumidify continuously and cannot select humidity Press mode button to exit cont...

Page 16: ...plug before moving the unit 3 The overall height of the tube should be lower than the drain to avoid water backflow and ensure smooth discharge X X 10cm or more NOTE At the Bucketless mode the hight...

Page 17: ...2 For some models When the unit is on if the bucket is full the compressor turns off and the fan turns off after 30 seconds for drying the water of the condenser then the unit will beep 8 times and th...

Page 18: ...not being used remove the pump drain hose from the outlet Press the pump drain hose outlet in and take the pump drain hose out from it Take the pump hose out from the unit Make sure do not let the wat...

Page 19: ...et must be in place and securely seated for the dehumidifier to operate The air filter behind the two flanks grille should be checked and cleaned at least every two weeks or more often if necessary NO...

Page 20: ...ead of upright as it should be The floor surface is not level Hose to connector or hose connection may be loose Intend to use the bucket to collect water but the back drain plug is removed This is nor...

Page 21: ......

Page 22: ...ations are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the service website pl...

Page 23: ...USER MANUAL OF SMART KIT IMPORTANT NOTE Read the manual carefully before connecting your Smart kit Wireless module Make sure to save this manual for future reference...

Page 24: ...CONTENTS SPECIFICATION PRECAUTIONS DOWNLOAD AND INSTALL APP USER REGISTRATION NETWORK CONFIGURATION HOW TO USE APP SPECIAL FUNCTIONS APP DECLARATION 1 2 3 4 5 6 7 8 1 1 2 2 3 8 9 11...

Page 25: ...ption WPA PSK WPA2 PSK encryption is recommended Due to different network situation control process may return time out sometimes If this situation occurs the display between board and APP may not be...

Page 26: ...o Wi Fi Wireless router Also the Wi Fi Wireless router has already connected to Internet before doing user registration and network configuration It is better to log in your email box and active your...

Page 27: ...ce has already been connected to the Wi Fi Wireless network which you want to use Also you need to forget other irrelevant Wi Fi Wireless network in case it influences your configuration process 1 2 A...

Page 28: ...Code Choose the network configuration method 6 Choose the Scan the QR code method Sacn the QR code on the unit 7 Or choose the Manual Setup method 8 Please enter password 9 Network configuration is s...

Page 29: ...forget other irrelevant Wi Fi Wireless network in case it influences your configuration process 1 2 Activate the AP mode Read the WIRELESS MODE IN OWNER S MANUAL for detailed operations Using iOS devi...

Page 30: ...Connect to the Wi Fi Wireless network 6 Please enter password 7 Network configuration is successful 8 6 Follow the above steps to enter AP mode 5...

Page 31: ...e device status still display offline If this situation occurs it is necessary to pull and refresh the device list on the APP and make sure the device status become online Alternatively user can turn...

Page 32: ...con to activate Press again to deactivate 6 Anti mould mode on some models Click Anti mould icon to activate Press again to deactivate 8 Pure mode on some models Click Pure icon to activate Press agai...

Page 33: ...l to find more information 7 SPECIAL FUNCTIONS Including Timer on Timer off Share device NOTE If the dehumidifier do not support the above function the function will be hided from the function list Sc...

Page 34: ...be controlled by multi users at the same time by Share Device function Click Share device 1 QR code display 2 The other users must log in the Midea Air APP then click Add Shared Device and scan the QR...

Page 35: ...limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not install...

Page 36: ...CD003IU APWIFI OBM...

Reviews: