1. I f t he cable is dam aged or needs replacing, t his should be done by an
aft er- sales t echnician using t he proper t ools, so as t o avoid any accident s.
2. I f t he appliance is being connect ed direct ly t o t he m ains supply, an om nipolar
circuit breaker m ust be inst alled wit h a m inim um gap of 3m m bet ween t he
cont act s.
3. The inst aller m ust ensure t hat t he correct elect rical connect ion has been
m ade and t hat it com plies wit h safet y regulat ions.
4. The cable m ust not be bent or com pressed.
5. The cable m ust be checked regularly and only replaced by a properly qualified
person.
24
Yellow / Green
Black
Brown
Blue
220-240V~
380-415V~
220-240V~
1
2
3
4
1
2
3
4
L1
L2
N
1
2
3
4
Yellow / Green
Black
Brown
Blue
220-240V~
2
3
4
N
L2
L1
1
Con n e ct in g t h e h ob t o t h e m a in s pow e r su pply
The power supply should be connect ed in com pliance wit h t he relevant st andard,
or a single- pole circuit breaker. The m et hod of connect ion is shown below.