Unlock screen

If the 

lock

 icon is on the screen, the controller is locked.

The following page is displayed:

Press any key, the 

lock

 icon will flash. Long press the ‘’UNLOCK’’ key. 

The 

lock

 icon will disappear, the interface can be controlled.

Setting the clock and date

• 

Press MENU, press 

caret-down

 6 times to SERVICE INFO press OK

• 

Press 

caret-right

 3 times to DISPLAY press OK

• 

Go to TIME press 

caret-right

 then use 

caret-up

 and 

caret-down

 to set the time hours 

and minutes, press OK

• 

Go to DATE press 

caret-right

 then use 

caret-up

 and 

caret-down

 to set the day and 

month, press OK

• 

Go to Buzzer press ON / OFF to silence the noise from the 
controller.

• 

Press back a few times to get to the front screen

Starting the unit in heating mode

Press 

caret-left

 to highlight the left hand side of the controller this is the 

heating side, press ON / OFF

The middle of the controller tells you what is happening now. In this 
case heating (the sun) is on, so the thermostats are calling. The unit 
will start the pump in 2 minutes and the compressor in 5 minutes.

Check the pipework is heating up and the header is getting warm. 
MAKE SURE there is no hot water going to the cylinder.

Note if you try to change the water temperature or turn the heating 
off a message shows. This unit is controlled from an external 
run signal and operates using the water settings for weather 
compensation you set earlier.

Starting the unit in hot water mode to 
heat the cylinder

Go back to the front screen, press 

caret-right

 to highlight the right side of the 

controller. This is the hot water setting.

When you highlight the DHW it tells you the DHW set temperature, 
when it’s not highlighted it shows the current DHW tank 
temperature. With it highlighted press ON / OFF the unit will start 
heating the cylinder

Note how the middle of the controller is now showing the tap to 
indicate its actually heating the tank.

Starting the unit

Starting the unit

Turning on or off cooling/

heating mode is controlled by

the room thermostat.

Please turn on or off cooling/

heating mode by the room

thermostat.

CONFIRM

OK

Summary of Contents for M-thermal Mono

Page 1: ...M thermal Mono ATW Heat Pump Quick Installation Manual...

Page 2: ...c 6 Piping the unit 7 Wiring Schematic 8 How it s going to work 10 Running the unit for the first time 11 Field settings 12 A glance of the user interface 15 Starting the unit 16 Operational data 18 F...

Page 3: ...c 6 Piping the unit 7 Wiring Schematic 8 How it s going to work 10 Running the unit for the first time 11 Field settings 12 A glance of the user interface 15 Starting the unit 16 Operational data 18 F...

Page 4: ...1295 397 429 760 256 105 225 792 161 8 10 12 14 16kW 1385 482 526 760 270 160 221 945 182 81 Installing the Outdoor Unit Boiler Position the outdoor unit so that the air flows into an open area where...

Page 5: ...1295 397 429 760 256 105 225 792 161 8 10 12 14 16kW 1385 482 526 760 270 160 221 945 182 81 Installing the Outdoor Unit Boiler Position the outdoor unit so that the air flows into an open area where...

Page 6: ...1x Pump 1x 28mm 3 port valve Filter Ball Glycol Header 32A Isolator 2x Electric Meter Optional Cylinder Immersion Timer Delivery Install Manual The water connections are flow at the top and the return...

Page 7: ...1x Pump 1x 28mm 3 port valve Filter Ball Glycol Header 32A Isolator 2x Electric Meter Optional Cylinder Immersion Timer Delivery Install Manual The water connections are flow at the top and the return...

Page 8: ...the header is wired into 10 live and 22 Neutral The remote controller can be wired in Cat 5 cable up to 20m long The blue hot water cylinder sensor is delivered 10m long it can be extended to 20m lon...

Page 9: ...the header is wired into 10 live and 22 Neutral The remote controller can be wired in Cat 5 cable up to 20m long The blue hot water cylinder sensor is delivered 10m long it can be extended to 20m lon...

Page 10: ...ersion heater make sure the internal thermostat on the immersion is set as high as possible 60 C Turn all thermostats down and underfloor heating off before you power up the heat pump Power up the uni...

Page 11: ...ersion heater make sure the internal thermostat on the immersion is set as high as possible 60 C Turn all thermostats down and underfloor heating off before you power up the heat pump Power up the uni...

Page 12: ...emote thermostat its got weather compensation and it has a hot water cylinder Now you have to test to see if its tubed and wired up OK T1SETH1 T1S T1S2 T4H1 T4H2 T4 T1SETH2 Test Run TEST RUN is used t...

Page 13: ...emote thermostat its got weather compensation and it has a hot water cylinder Now you have to test to see if its tubed and wired up OK T1SETH1 T1S T1S2 T4H1 T4H2 T4 T1SETH2 Test Run TEST RUN is used t...

Page 14: ...n on or o the function in the menu structure Long press for unlocking locking the controller Go to the next step when programming a schedule in the menu structure con rm a selection enter a submenu in...

Page 15: ...n on or o the function in the menu structure Long press for unlocking locking the controller Go to the next step when programming a schedule in the menu structure con rm a selection enter a submenu in...

Page 16: ...his case heating the sun is on so the thermostats are calling The unit will start the pump in 2 minutes and the compressor in 5 minutes Check the pipework is heating up and the header is getting warm...

Page 17: ...his case heating the sun is on so the thermostats are calling The unit will start the pump in 2 minutes and the compressor in 5 minutes Check the pipework is heating up and the header is getting warm...

Page 18: ...hat there is air in the system or the water level in the system is less than the required minimum OPERATION PARAMETER 01 OPERATE MODE COOL ADDRESS SV1 STATE ON ONLINE UNITS NUMBER 1 SV2 STATE OFF SV3...

Page 19: ...hat there is air in the system or the water level in the system is less than the required minimum OPERATION PARAMETER 01 OPERATE MODE COOL ADDRESS SV1 STATE ON ONLINE UNITS NUMBER 1 SV2 STATE OFF SV3...

Page 20: ...not liable for errors or omissions All brand product service names and logos are trademarks and or registered trademarks of their respective owners and are hereby recognized and acknowledged v290920 F...

Reviews: