5
INSTALLATION INSTRUCTIONS
Fig.4
Wall
Indoor
Outdoor
5
-7
m
m
Fig.6
Fig.5
Indoor unit installation
2. Drill a hole in the wall
Note:
1. Fit the Installation Plate
1 . F it th e i nstal l a t i o n p late ho r izontally
o n s tructural p a rts of t h e wal l w ith
s p a c e s a round t h e ins t a l l a t i o n plat e .
2 . I f th e w all is m ade of b rick, co n c rete
o r t he li k e , d rill ei g h t ( 8) 5m m d iamet e r
h o l e s i n th e w all.Ins e r t C lip an c h o r f or
a p p r o p r iate mo u n t i n g s crew s .
3 . F it th e i nstal l a t i o n p late on t he wa l l
w i t h e ight (8 ) t ype ?A ? s crews .
Fit the Installation Plate and drill
holes in the wall according to the
wall structure and corresponding
mounting points on the installation
plate. The installation plate provided
with the machine is differrent according
to the models.
(
D i m e n s i o ns are i n ? mm? u n l ess
o therw i s e s tated)
1. Determine hole positions according
to the diagramdetailed in Fig.5. Drill
one (1) hole (
φ
65mm) slanting slightly
to outdoor side.
2. Always use wall hole conduit when
drilling metal grid, metal plate or the like.
Correct orientation
of Installation Plate
Model C
Model D
150mm or more to ceiling
Indoor unit outline
Installation plate
292
Right rear side
refrigerant
pipe hole
φ
65
Left rear side
refrigerant
pipe hole
φ
65
120mm or
more to wall
120mm or
more to wall
920
45
185
150
45
A
45
B
Right rear side
refrigerant
pipe hole
φ
65
Installation plate
Indoor unit outline
Left rear side
refrigerant
pipe hole
φ
65
150mm or more to ceiling
120mm or
more to wall
120mm or
more to wall
Model A (A: 710, B: 250, C:100, D: 110)
Model B (A: 790, B:265, C:100, D: 150)
90
45
C
D
120mm or more
from the wall
120mm or more
from the wall
4
5
150mm or more from the ceiling
Indoor Unit Outline
Hooked Part
100
65
65
120
4
5