Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
23
Troubleshooting by Error Code
Common Check Procedures
Temperature Sensor Check
Disconnect the temperature sensor from PCB, measure the resistance value with a tester.
Temperature Sensors.
Room temp. (T1) sensor,
Indoor coil temp. (T2) sensor,
Outdoor coil temp.(T3) sensor,
Outdoor ambient temp.(T4) sensor,
Compressor discharge temp.(Tp) sensor.
Measure the resistance value of each winding by using the multi
−
meter.
Compressor Checking
Measure the resistance value of each winding by using the tester.
Fig. 17 — Compressor Checking
Table 15 — Compressor Checking
Fig. 18 — Compressor Checking
POSITION
RESISTANCE VALUE
ASN98D22UFZ
ATM115D43UFZ2
ATF235D22UMT
Blue - Red
1.57
(20°C/68°F)
1.87
(20°C/68°F)
0.75
(20°C/68°F)
Blue - Black
Red - Blue