MCAC-RTSM-2012-01 M-thermal Technical Manual
10
5.2 Specifications of Hydraulic indoor unit
Hydraulic indoor unit
SMK-120/CSD80GN1
SMK-140/CSD80GN1
Power supply
Ph-V-Hz
3-380
~
415-50
3-380
~
415-50
Function
Types
Heating &Cooling
Heating &Cooling
Space
Heating
℃
15
~
55
15
~
55
Space
Cooling
℃
7
~
22
7
~
22
Sanitary Hot
Water
℃
35
~
60
35
~
60
Max. current
A
13.8
13.8
Noise level
dB(A)
32
32
Unit
Dimension
(W×H×D)
mm
900×500×375
900×500×375
Packing
(W×H×D)
mm
1110×610×510
1110×610×510
Net/gross
weight
kg
63/75
63/75
E-heater
Size
kW
4
4
Quantity
1
1
specification
Ph-V
3-400
3-400
E-heater(standby)
Size
kW
4
4
Quantity
1
1
specification
Ph-V
3-400
3-400
Water pipeline
Water inlet
pipe
mm
DN32
DN32
Water outlet
pipe
mm
DN32
DN32
Loading Quantity
20'/40'/40H
Pcs
66/138/184
66/138/184
The testing Condition:
1. Heating: Outdoor temp. 7/6
℃
(DB/WB), inlet water temp. 30
℃
, outlet water temp. 35
℃
.
2. Cooling: Outdoor temp. 35/24
℃
(DB/WB), inlet water temp. 12
℃
, outlet water temp. 7
℃
.