17
6.5 MSC-12CRN1
SUMMER
OUTDOOR
TEMPERATURE
DRY
Indoor
Conditions
25ºC 30ºC 35ºC 40ºC 45ºC 50ºC
Total
capacity
kW 3.276 3.187 3.105 2.821 2.746 2.621
Sensitive
capacity
kW
2.567 2.457 2.413 2.287 2.21 2.087
21ºC D
15ºC W
Input
kW.
0.89 1.01 1.082 1.188 1.243 1.337
Total
capacity
kW 3.663 3.503 3.315 3.148 3.076 2.932
Sensitive
capacity
kW
2.918 2.766 2.725 2.557 2.453 2.334
24ºC D
17ºC W
Input
kW.
0.915 1.033 1.121 1.228 1.278 1.367
Total capacity kW
3.86
3.7
3.5
3.371 3.215 3.125
Sensitive capacity kW
3.039
2.913
2.832
2.645 2.567 2.419
27ºC D
19ºC W
Input kW.
0.944
1.048
1.1
1.253 1.312 1.426
Total
capacity
kW 4.215 4.1 3.845 3.601 3.501 3.313
Sensitive
capacity
kW
3.12 2.939 2.891 2.715 2.589 2.503
32ºC D
23ºC W
Input
kW.
0.969 1.088 1.189 1.302 1.349 1.455
6.6 MSC-12HRN1
SUMMER
OUTDOOR
TEMPERATURE
DRY
Indoor
Conditions
25ºC 30ºC 35ºC 40ºC 45ºC 50ºC
Total
capacity
kW 3.276 3.187 3.105 2.821 2.746 2.621
Sensitive
capacity
kW
2.567 2.457 2.413 2.287 2.21 2.087
21ºC D
15ºC W
Input
kW.
0.89 1.01 1.082 1.188 1.243 1.337
Total
capacity
kW 3.663 3.503 3.315 3.148 3.076 2.932
Sensitive
capacity
kW
2.918 2.766 2.725 2.557 2.453 2.334
24ºC D
17ºC W
Input
kW.
0.915 1.033 1.121 1.228 1.278 1.367
Total capacity kW
3.86
3.7
3.5
3.371 3.215 3.125
Sensitive capacity kW
3.039
2.913
2.832
2.645 2.567 2.419
27ºC D
19ºC W
Input kW.
0.944
1.048
1.1
1.253 1.312 1.426
Total
capacity
kW 4.215 4.1 3.845 3.601 3.501 3.313
Sensitive
capacity
kW
3.12 2.939 2.891 2.715 2.589 2.503
32ºC D
23ºC W
Input
kW.
0.969 1.088 1.189 1.302 1.349 1.455
Downloaded from AC-Manual.com Manuals