16
6.4 MSC-09HRN1
SUMMER
OUTDOOR
TEMPERATURE
DRY
Indoor
Conditions
25ºC 30ºC 35ºC 40ºC 45ºC 50ºC
Total
capacity
kW 2.42 2.41 2.24 2.03 1.87 1.75
Sensitive
capacity
kW
1.72 1.69 1.65 1.53 1.43 1.36
21ºC D
15ºC W
Input
kW.
0.72 0.75 0.8 0.84 0.89 0.97
Total
capacity
kW 0.65 2.55 2.45 2.24 2.11 1.98
Sensitive
capacity
kW
1.83 1.73 1.7 1.63 1.63 1.57
24ºC D
17ºC W
Input
kW.
0.68 0.76 0.81 0.88 0.93 1.02
Total capacity kW
2.89
2.8
2.6
2.45 2.23 2.05
Sensitive capacity kW
1.99
1.95
1.81
1.78 1.66 1.63
27ºC D
19ºC W
Input kW.
0.65
0.78
0.82
0.92 0.96 1.03
Total
capacity
kW 3.03 2.98 2.92 2.83 2.69 2.46
Sensitive
capacity
kW
2.05 1.88 1.96 1.87 1.87 1.85
32ºC D
23ºC W
Input
kW.
0.65 0.8 0.86 0.95 0.99 1.08
WINTER
OUTDOOR
CONDITIONS
Indoor
Conditions
12ºC D
11ºC W
7ºC D
6ºC W
4ºC D
3ºC W
0ºC D
-1ºC W
-4ºC D
-6ºC W
-7ºC D
-8ºC W
Capacity
kW 3.75 3.38 3.02 1.97 1.59 1.52
15ºC
Input
kW.
0.97 0.84 0.73 0.65 0.62 0.63
Capacity
kW 3.52 3.26 2.94 1.84 1.6 1.49
18ºC
Input
kW.
0.98 0.86 0.78 0.7 0.65 0.68
Capacity kW
3.4
3
2.85 1.82 1.56 1.5
20ºC
Input kW.
1.02
0.82
0.8 0.74 0.68 0.67
Capacity
kW 3.11 2.93 2.72 1.73 1.58 1.42
22ºC
Input
kW.
1.06 0.93 0.82 0.77 0.71 0.65
Downloaded from AC-Manual.com Manuals