14
6. Capacity table
6.1 MSC-07CRN1
SUMMER
OUTDOOR
TEMPERATURE
DRY
Indoor
Conditions
25ºC 30ºC 35ºC 40ºC 45ºC 50ºC
Total
capacity
kW 2.04 1.94 1.7 1.61 1.53 1.41
Sensitive
capacity
kW
1.52 1.41 1.39 1.32 1.19 1.07
21ºC D
15ºC W
Input
kW.
0.53 0.58 0.6 0.67 0.73 0.8
Total
capacity
kW 2.14 2.05 1.93 1.81 1.73 1.51
Sensitive
capacity
kW
1.61 1.46 1.45 1.54 1.23 1.15
24ºC D
17ºC W
Input
kW.
0.54 0.6 0.62 0.7 0.74 0.82
Total capacity kW
2.31
2.24
2.1
1.95 1.7 1.65
Sensitive capacity kW
1.78
1.65
1.56
1.43 1.26 1.28
27ºC D
19ºC W
Input kW.
0.57
0.62
0.64
0.71 0.75 0.83
Total
capacity
kW 2.33 2.36 2.31 2.25 2.15 2.03
Sensitive
capacity
kW
1.83 1.67 1.65 1.64 1.57 1.52
32ºC D
23ºC W
Input
kW.
0.58 0.64 0.66 0.73 0.8 0.86
6.2 MSC-07HRN1
SUMMER
OUTDOOR
TEMPERATURE
DRY
Indoor
Conditions
25ºC 30ºC 35ºC 40ºC 45ºC 50ºC
Total
capacity
kW 2.04 1.94 1.7 1.61 1.53 1.41
Sensitive
capacity
kW
1.52 1.41 1.39 1.32 1.19 1.07
21ºC D
15ºC W
Input
kW.
0.53 0.58 0.6 0.67 0.73 0.8
Total
capacity
kW 2.14 2.05 1.93 1.81 1.73 1.51
Sensitive
capacity
kW
1.61 1.46 1.45 1.54 1.23 1.15
24ºC D
17ºC W
Input
kW. 0.54 0.6 0.62 0.7 0.74 0.82
Total capacity kW
2.31
2.24
2.1
1.95 1.7 1.65
Sensitive capacity kW
1.78
1.65
1.56
1.43 1.26 1.28
27ºC D
19ºC W
Input kW.
0.57
0.62
0.64
0.71 0.75 0.83
Total
capacity
kW 2.33 2.36 2.31 2.25 2.15 2.03
Sensitive
capacity
kW
1.83 1.67 1.65 1.64 1.57 1.52
32ºC D
23ºC W
Input
kW.
0.58 0.64 0.66 0.73 0.8 0.86
Downloaded from AC-Manual.com Manuals