background image

GD  Midea  Refrigerant  Equipment  Co.  Ltd                                                                              Service  manual  for  F  Dehumidifier 

Worn bearings 

Replace the motor if knocking sounds continue w hen 

running or loose, or the motor hums or noise appears to be 

internal while running. 

Excessive 

noise 

Copper tubing 

Remove the cabinet and carefully rearrange tubing not to 

contact cabinet, compress or, shroud and barrier. 

Voltage 

Check voltage. Call an electrician if not within limits. 

Wiring 

Check the w ire connections, if loose, repair or replace the 

terminal. If wires are of f, refer to wiring diagram for identification, 

and replace. Check w ire locations. If not per wiring diagram, 

correct. 

Main PCB failure 

Replace the main PCB if open. 

Capacitor (Discharge 

capacitor before testing) 

Check the capacitor. Replace if not within 10% of 

manufacturers rating. Replace if shorted, open, or damaged. 

Humidity sensor 

Replace if shorted, open, or damaged. 

Compress or 

will not run while 

fan motor runs 

Compressor 

Check the compressor f or open circuit or ground. If open or 

grounded, replace the compressor. 

Air filter 

Clean or replace if restricted. 

Condenser and 

Evaporator 

Clean or replace if restricted. 

Fan motor 

Check the fan capacitor and replace if not within 10% of 

manufactures rating. 

Room structure 

Take proper measures to make the door and window s 

sealed w ell if gap is found. 

Air flow 

Clean or remove if any barrier is found to block the 

inlet/outlet wind flow of the unit. 

Less refrigerant 

Check the tubes for reasons of leakage. Recycle the 

refrigerant, correct the leakage points and recharge. 

Capillary tube 

Regulate the flow if capillary tube and make the evaporating 

temperature appropriate if the evaporator is frosted. 

Insufficient 

capacity 

Compress   

The inlet and outlet valve of the compressor is damaged, 

making the low pressure connected with the high pressure. The 

refrigerating system is difficult to produce high pres sure and low 

pressure. Replace the compressor after checking f or the reason. 

Refrigerant 

The amount of the refrigerant is too much, making the 

compressor load too big. Recycle and recharge the refrigerant 

after checking for the reason. 

Stop instantly 

after  

startup. 

Compressor 

The compressor is heat stuck. Replace after checking for the 

reason. 

Humidity sensor 

Check and replace if the Humidity sensor is open or 

damaged. 

The 

compressor not to 

stop even the room 

humidity has got to 

the setting value. 

Main PCB 

Check and replace the main PCB   

The unit starts 

and s tops 

Power supply 

The input power supply voltage is too low . Call an electrician 

if not within limits. 

Summary of Contents for CE-CF0.3BD/N3-F

Page 1: ...0 Website www mideaaircon com Service manual CAUTION BEFORE SERVICING THE UNIT READ THE SAFETY PRECAUTIONS IN THIS MANUAL ONLY FOR AUTHORIZED SERVICE PERSONNEL MODELS CE CF0 3BD N3 F CE CFZ0 3BD N3 F ...

Page 2: ...ecautions prior to servicing the unit 1 1 SAFETY PRECAUTIONS 1 When servicing the unit set the POWER SWITCH to OFF and unplug the power cord 2 Inspect the service cord for damage or wear If a short circuit is found replace all parts which have been overheated or damaged by the short circuit 3 After servicing the unit make an insulation resistance test to protect the customer from being exposed to ...

Page 3: ...nit is turned on and dark after the unit is turned off 3 FULL WATER indicator Lights up when the bucket is full and the unit stops operating 4 CONTINUE indicator Lights up when the unit is on CONTINUOUS DEHUMIDIFYING mode 5 HUMIDITY UP Button When the unit is operating the setting humidity will go up by pressing this button every time the range of justment is from 35 RH to 80 RH 6 HUMIDITY DOWN Bu...

Page 4: ...an motor will work same as the compressor 2 5 Compressor delay start When the mode is changed but the compressor does not start or the unit restart after stop working if the compressor accord with it s starting condition the fan motor will start immediately while the compressor will delay 3 seconds to re start 2 7 Protection and failure mode 2 7 1 Water full protection When the water tank is full ...

Page 5: ... temperature sensor is defective the motors of the compressor and the fan will be shut down and the power indicator will flash at 5 Hz Power indicator flashes at 5 Hz The connector CN3 in main PCB is loosed Place it properly Pipe temperature sensor trouble Replace pipe temperature sensor Trouble in input circuit of water level switch of drive board components Water level switch broken Replace swit...

Page 6: ...5 3 1 3 Humidity sensor check 3 1 4 Fail to start or fail to start motor 3 1 5 Abnormal noise Humidity display is chaos Water on the Humidity sensor board Dry it over heat Humidity sensor board trouble or main PCB defective Replace humidity sensor board trouble or main PCB ...

Page 7: ...ct w ire Refer to wiring diagram for terminal identification Loose Repair or replace loss e terminal Main PCB failure Select fan speed and Check the voltage of P1 P2 on main PCB Replace the main PCB if no voltage Capacitor Discharge capacitor before testing Test capacitor Replace if not within 10 of manufacture s rating replace if shorted open or damaged Fan motor w ill not run Will not rotate Fan...

Page 8: ...nd replace if not within 10 of manufactures rating Room structure Take proper measures to make the door and window s sealed w ell if gap is found Air flow Clean or remove if any barrier is found to block the inlet outlet wind flow of the unit Less refrigerant Check the tubes for reasons of leakage Recycle the refrigerant correct the leakage points and recharge Capillary tube Regulate the flow if c...

Page 9: ...ce manual for F Dehumidifier 8 Humidity sensor Replace it frequently Main PCB Check and replace the main PCB 4 WIRING DIAGRAM 4 1 For models 5 EXPLODED VIEWS See attached files 6 SPECIFICATIONS See attached files CE CF0 3BD N3 F CE CFZ0 3BD N3 F ...