9.2.9 Over voltage or too low voltage protection diagnosis and solution(P1)
Check if the power
supply is normal.
C h e c k i f a l l t h e
connections are good.
Disconnect the unit with power supply and try to
restart the unit when power supply gets normal.
No
Yes
No
Correct the connections.
Yes
Check if the voltage between
P and N is around DC 320V.
Replace outdoor control PCB.
No
9.2.10 Inverter compressor drive error diagnosis and solution(P4)